ColorWise Pro Tools for Windows and Mac OS computers are fundamentally the same.
The windows and dialog boxes illustrated are the Windows versions.
The windows and dialog boxes illustrated are the Windows versions.
N
OTE
:
Changing the calibration has the potential to affect
all
jobs for
all
users, so you may
want to limit the number of people authorized to perform calibration.
T
O
CALIBRATE
THE
COPIER
USING
C
ALIBRATOR
1.
Launch ColorWise Pro Tools and connect to the Fiery.
For instructions on configuring the connection for ColorWise Pro Tools, see
Getting Started
.
2.
Click Calibrator.
The EFI ED-100 is available as a measurement method. This information is provided to
Calibrator by the Fiery. If the option does not appear, make sure you are connected to a
Fiery that supports the EFI ED-100. Not all Fierys support the EFI Densitometer ED-100.
Calibrator by the Fiery. If the option does not appear, make sure you are connected to a
Fiery that supports the EFI ED-100. Not all Fierys support the EFI Densitometer ED-100.
N
OTE
:
It is very important that the copier you are calibrating and the computer that the
EFI ED-100 is connected to are connected to the same Fiery server. Also, be sure to print
the measurement patches from the copier you are calibrating, because the EFI ED-100 uses
formulas specific to the copier to convert the raw EFI ED-100 measurements into
ColorWise Calibrator compatible densities.
the measurement patches from the copier you are calibrating, because the EFI ED-100 uses
formulas specific to the copier to convert the raw EFI ED-100 measurements into
ColorWise Calibrator compatible densities.