Xerox Phaser 840 文件

下载
页码 152
Advanced Features and Troubleshooting Manual
129
Regulatory Information and Specifications
10
MSDS for CleanTex Alcopad 
Section 1 – Product Identification
Trade name and Tektronix part number:
Alcopad — 016-1595-00
PRODUCT IDENTIFICATION NUMBERS: 806B, 806C, 806H, 806T, 806Z, 806
CHEMICAL NAME AND SYNONYMS: Isopropyl Alcohol
CHEMICAL FORMULA: CH
2
CH(OH)CH
3
EMERGENCY TELEPHONE NUMBERS:CHEMTREC (Transportation): 800-424-9300
Product Use:  Tektronix Phaser
® 
840 color printer 
Section 2 – Information On Ingredients 
COMPONENT
CAS#
%
OSHA PEL (ppm)
ACGIL TLV (ppm)
isopropyl alcohol
67-63-0
91.0
400
400
Deionized water
7732-18-5
9.0
NA
NA
Section 3 – Hazards Identification
Product is distributed as a single use, presaturated pad, in which all the liquid is absorbed by the applicator.  Isopropyl 
alcohol is a flammable liquid.  Eye contact will cause local irritation and burning sensations with possible injury if not 
removed promptly.  Repeated or prolonged contact with skin may produce irritation and cause dermatitis.  Exposure 
above TLV may cause irritation of respiratory tract and eyes along with headaches, dizziness and CNS effects.  May 
be harmful if swallowed.
Carcinogenicity (OSHA/NTP/IARC/ACGIH):  Not Listed
Medical Conditions Aggravated by Exposure:  Not Listed
Section 4 – First Aid Measures
EYE CONTACT:  Flush with water for 15 minutes, including under eyelids.  Get Medical help.
SKIN CONTACT:  Flush with water
INHALATION:  Remove to fresh air.  Keep at rest.  Restore and/or support breathing as needed.  Get prompt Medical 
attention.
INGESTION:  In the unlikely event of ingestion of a wiper, first aid measures should focus on removal of the object and 
preventing choking.  Once removed, keep affected person at rest.  Call physician immediately.
Section 5 – Fire Fighting Measures 
FLASH POINT (TCC):  56 degrees F
FLAMMABLE LIMITS (% BY VOLUME): LEL: NA   UEL: NA
AUTOIGNITION TEMPERATURE degrees F (degrees C): NA
EXTINGUISHING MEDIA:  Isopropyl  alcohol fires may be extinguished using carbon dioxide, dry chemical or alcohol 
foam.  Water may be used to cool containers exposed to the fire.
UNUSUAL FIRE OR EXPLOSION HAZARDS:  Isopropyl alcohol may release vapors which may ignite at or above 
flash point.
NFPA RATING:  HEALTH(1)
FLAMMABILITY(3)
REACTIVITY(0)
Formulation is classified as an OSHA Class IB Flammable Liquid
NA = Not Available 
Section 6 – Accidental Release Measures
Since the isopropyl alcohol solution is completely absorbed by the applicator and the amount of isopropyl alcohol per 
applicator is small, the chance of a significant spill occurring is small. In the event however, a significant amount of 
liquid is released, ventilate the area, especially low areas where vapors may collect and remove all sources of ignition.  
Cleanup personnel need protection against liquid contact and vapor inhalation.