Advanced Features and Troubleshooting Manual
163
Regulatory Information and Specifications
10
Specifications
Operating range:  temperature and humidity
The operating range is contained within the temperature/humidity space defined by 
the following points: 
Celsius:
15.5
o
 C, 10% RH
32.2
o
 C / 10% RH
32.2
o
 C / 60% RH
25.5
o
 C / 80% RH
15.5
o
 C / 80% RH
Fahrenheit:
60
o
 F, 10% RH
90
o
 F /  10% RH
90
o
 F / 60% RH
78
o
 F / 80% RH
60
o
 F / 80% RH
The best print quality is obtained within these limits:
15.5
o
 to 25.5
o
 C (60
o
 to 78
o
 F), and 20% to 65% relative humidity
Temperature
Non-operating:  0
o
 C to 40
o
 C (32
o
 F to 104
o
 F)
Storage:  (without paper, transparencies, or consumables):  –20
o
 C to +60
o
 C 
(–4
o
 F to +140
o
 F)
Humidity
Non-operating:  10% to 90% relative humidity, non-condensing
Altitude
Operating:  0 to 2,500 m (8,000 ft.).  
Non-operating:  0 to 4000 m (13,125 ft.)
Primary voltage ranges
90 - 132 VAC, 110 VAC nominal
198 - 264 VAC, 220 VAC nominal
Frequency range
50 to 60 Hz
Primary fusing
125 VAC, 10 Amps and 8 Amps
250 VAC, 5 Amps and 4 Amps
(Not user-accessible)