Xerox Phaser 340 用户指南

下载
页码 288
Using Different Printer Language Modes
D
Printing Reference
D-3
3.
Locate the installed files in the PHSR340 subdirectory inside the 
PHSRTOOL directory on your hard disk, and open the 
CONFIG.PS file in a text editor.
The default values for the printer are 0 seconds for the job timeout and 40 
seconds for the wait timeout.  A timeout value of 0 indicates no timeout; the 
printer waits indefinitely.
In the following example, the timeouts are set to their default values.  
3 dict begin
   /Password() def
/JobTimeOut 0 def
/WaitTimeOut 40 def
currentdict end setsystemparams
1 dict begin
   currentpagedevice /ManualFeedTimeout known
{  /ManualFeedTimeout 60 def  } if
currentdict end setpagedevice
4.
To change CONFIG.PS to specify different timeouts, substitute 
new values for 0 and 40 in the JobTimeOut and 
WaitTimeOut lines. 
Permitted timeout values are as follows:
JobTimeOut:  0 to 999
WaitTimeOut:  0, or 15 to 999
ManualFeedTimeout:  0 to 999
To specify no timeout, use 0
Note
To avoid timeouts or job cancellation on Windows multiple-page 
or multiple-copy print jobs, you may want to set the 
WaitTimeOut to a high value or to 0 (zero).