Xerox DocuTech 6100 Production Publisher 用户指南

下载
页码 168
Recommended Shift Preventative Maintenance Plan 
 
DT6180 HandyBook 
 
27  
3.  Recommended Shift Preventative Maintenance Plan 
 
Regular operator maintenance of your equipment is likely to improve overall 
performance.  The maintenance could be done at the beginning or end of the 
shift,  which ever is decided upon by your team.  The following are suggested 
maintenance activities. 
 
1.  Clean All Sensors.   
 
2.  Full Shutdown and Restart. 
 
3.  Check and Fill Fuser Agent. 
 
4.  Shift handoff communication between operators regarding system issues 
encountered on previous shift. 
 
5.  Clean Dicorotron Shields (NOTE: Only perform this task if you have been 
eXcellerate Trained.  Refer to your eXcellerate  training materials for 
details
.) 
 
 
 
Shift preventative Maintenance Plan Details 
 
1. 
Clean All Sensors
.   
 
Clean Finisher Entrance Sensor (Q1201)
  
Clean the Bin A Bindexer Sensor (Q1205)
  
Clean the Bin B Bindexer Sensor (Q1206)
 
Clean the Binder Tape Guide Sensor (Q1213)
 
Clean the Bindexer Sensors (Q1205, Q1206, Q1207)
 
Clean the Bins Exit Sensors (Q1222)Error! Bookmark not defined.
 
Clean the Front Stack (Q1227), Rear Stack Height (Q1218), and Set Path (Q1221) 
Sensors
 
Clean the Fuser (Q1010) and Prefuser Sensors (Q1009)
 
Clean the Post Inverter (Q1202) and Output Transport (Q1203) Sensors
 
Clean the Pre-Fuser Sensor (Q1009)
 
Clean the Registration Transport Sensor (Q861)
 
Clean the Set Path Sensor (Q1221)
 
Clean the Tape Binder Area