Xerox DocuColor 12 Printer with Fiery X12 产品宣传页
3
3-5
Using a densitometer
Checking calibration status
You can check whether the Fiery is calibrated, which calibration set and output profile
were used, and when the copier was last calibrated:
were used, and when the copier was last calibrated:
• Print a Configuration page or Test Page from the Control Panel or the Command
WorkStation.
• When you select a calibration set in Calibrator, the last calibration and the user who
performed it are displayed.
Using a densitometer
ColorWise Pro Tools are designed to work with the X-Rite DTP32 reflection
densitometer where color measurements are entered automatically.
densitometer where color measurements are entered automatically.
N
OTE
:
Measurements from other densitometers can be input using a simple ASCII file
Setting up the densitometer
Before you calibrate the Fiery, you need to connect, configure, and calibrate the
densitometer to prepare for measuring the printed patches (see “Calibrating the
densitometer” on page 3-8). For additional information about setting up and using the
densitometer, see the documentation included with it.
densitometer to prepare for measuring the printed patches (see “Calibrating the
densitometer” on page 3-8). For additional information about setting up and using the
densitometer, see the documentation included with it.