Craftsman T825011L 用户手册

下载
页码 7
IMPORTANT: BEFORE FIRST USE, perform the following Air Purge Procedure to remove any air 
that may have been introduced into the hydraulic system as a result of product shipment and 
handling.
AIR PURGE PROCEDURE
6
Screwdriver
TURN HANDLE CLOCKWISE
Turn handle clockwise until it 
stops to ensure that release 
valve is closed.
PURGE AIR
With a flat blade screwdriver, 
push the oil fill plug slightly to 
the side to purge trapped air 
from system. 
TURN HANDLE CLOCKWISE
Turn the handle clockwise until it 
stops.
RAPIDLY PUMP
Rapidly pump the handle 6 - 8 times. 
Leave handle in down position to 
expose oil fill plug.   
READY TO USE
Jack is now ready for use. Check 
for proper pump action. 
ASSEMBLE AND INSERT HANDLE
See ASSEMBLY on page 3 to assemble 
handle. Loosen handle socket screw. 
Insert end of handle into handle socket.
Tighten screw.
TURN HANDLE 
COUNTERCLOCKWISE
Turn handle counterclockwise 
2 full turns to fully open 
release valve.
7
10 am - 7 pm, Central Time,
NOTE: Repeat this Air Purge Procedure whenever 
the jack displays reduced lifting performance.
66
Oil Fill Plug