HE240, HE280 HUMIDIFIER AND INSTALLATION KIT
19
69-2686EF—01
Low 
humidity
Furnace blower 
not operating.
• Reset circuit breaker or check for blown fuse.
• Check that the furnace power is on.
• Check all external wiring connections.
• Check the humidity control setting.
• Verify that pressure switch tubing isn't 
pinched or obstructed.
• Call a professional heating contractor.
Rapid air changes. 
Drafts (cold air is 
dry and is an 
added load to the 
humidifier).
• Keep doors and windows closed.
• Close fireplace damper when not in use.
• Keep exhaust fan running time to a minimum.
• Seal around doors and windows.
Damper in 
“summer” position
• Set damper blade to "winter" position to allow 
humidification.
High 
humidity
Condensation on 
walls.
• Turn off humidity control and water until 
condensation is completely evaporated.
Heavy 
condensation on 
windows.
• Turn humidity control down low enough to 
eliminate condensation caused by moisture 
from bathing, mopping, cooking, etc. If 
moisture persists, more ventilation is needed.
Table 4. Troubleshooting Humidifier. (Continued)