10. For Air Treatment Systems, wait ten minutes for the 
airflow sensor to calibrate. During this time, the furnace 
fan must remain off.
NOTE: Failure to wait ten minutes for the airflow sensor to 
calibrate before powering the system fan causes the 
airflow sensor to incorrectly calibrate and the device 
to incorrectly function. If this occurs, remove power to 
the furnace or turn off the system fan, wait ten 
minutes, and then resume normal fan operation.
11. Verify that ultraviolet lamp is operating by viewing only 
through the lamp light indicator on the lamp handle. 
Never look directly at your bulbs while illuminated.
12. Reconnect power to your heating and cooling system.
CAUTION
UV Lamp Burn Hazard.
Harmful to bare skin.
Can cause severe burns.
Disconnect power 15 minutes before removing 
ultraviolet bulb(s).
Bulb Replacement
Replacement of the bulb in your ultraviolet lamp when the LED 
is solidly lighted is required to maintain effectiveness.
1. Obtain the correct replacement bulb for your unit. See 
Table 1.
2. Disconnect power to your heating and cooling system.
3. Unplug or turn off power to your UV System and allow 
the lamp to cool for at least 15 minutes.
4. Rotate the lamp handle counterclockwise and gently pull 
the lamp handle to remove the bulb(s). See Fig. 11.
5. If you have a SnapLamp™ handle, follow steps 5 and 6; 
otherwise, proceed to step 7. Grasp the SnapLamp™ 
handle in one hand and the lamp glass in the other and 
pull straight apart. See Fig. 16.
Fig. 16. Disconnect lamp glass from SnapLamp™ handle. 
6. Insert the new lamp glass into the SnapLamp™ handle 
by aligning the notch and pushing straight together. See 
Fig. 17.
Fig. 17. Replace lamp glass in SnapLamp™ handle.
7. Insert the lamp handle into the base with the lamp light 
indicator at the eleven o’clock position. Continue pushing 
and gently rotating counterclockwise until the lamp 
handle inserts fully into the base. See Fig 4.
8. Rotate the lamp clockwise until it snaps into place with 
the lamp light indicator aligned with the raised button on 
the unit cover. See Fig. 6.
9. Reconnect power to your UV System.
10. For UV Air Treatment Systems, wait ten minutes for the 
airflow sensor to calibrate. During this time, the furnace 
fan must remain off.
NOTE: Failure to wait ten minutes for the airflow sensor to 
calibrate before powering the system fan causes the 
airflow sensor to incorrectly calibrate and the device 
to incorrectly function. If this occurs, remove power to 
the furnace or turn off the system fan, wait ten 
minutes, and then resume normal fan operation.
WARNING
UV Light Hazard.
Harmful to bare skin and eyes.
Can cause temporary or permanent loss of vision.
Never look at bulbs while illuminated. 
View illumination only through lamp light indicator 
located on lamp handle.
To prevent exposure to ultraviolet light, disconnect 
power to ultraviolet system before servicing any part of 
heating and air conditioning system.
11. Verify that your ultraviolet lamp is operating by viewing 
only through the lamp light indicator on the lamp handle. 
Never look directly at your bulb while it is illuminated.
12. Reconnect power to your heating and cooling system.
13. Press and hold the reset button for five seconds to reset 
the internal timers.
Table 1. Select a Replacement Bulb/Handle Assembly
or Replacement Bulb.
Unit Description
Replacement 
Bulb/Handle 
Assembly
SnapLamp™ 
Replacement 
Bulb
UV100E1043
Air Treatment System
UC100E1006
UC18W1004
UV100E2009
Air Treatment System
UC100E1030
(two required)
UC36W1006
(two required)
UV100E3007
Surface Treatment 
System
UC100E1030
UC36W1006
M22851
M22853