Cisco Cisco UCS C3160 Rack Server 数据表

下载
页码 98
Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
25
RAID Volumes and Groups
When creating each RAID volume, follow these guidelines:
Use the same capacity for each drive in each RAID volume
For embedded software RAID or the embedded software RAID 5 key upgrade:
— Use only SATA HDDs
— Embedded software RAID has two ports and each port can control 4 drives, for 8 
drives total. 
— Each set of 4 SATA HDDs for a port must be in separate RAID volumes. 
— You cannot mix drives across ports to create a RAID volume. 
— For more details, see 
.
For the Cisco 12G SAS modular RAID controller upgrade:
— Use either all SAS HDDs, all SAS SSDs, or all SATA SSDs in each RAID volume
The number of RAID groups (virtual drives) supported per RAID controller is as follows:
Embedded RAID = 8
Cisco 12G SAS Modular RAID controller = 64
Select Controller Options
Select one of the following:
Embedded software RAID (this is the default if no other selection is made), or
Embedded software RAID 5 key upgrade option for internal drives (see 
or
One Cisco 12G SAS modular RAID controller or Cisco 12 Gbps Modular SAS HBA (see 
), or
Mixed controllers:
— One Cisco 12G SAS modular RAID controller or one Cisco 12 Gbps Modular SAS HBA 
and 
— One or two Cisco 9300-8E 12G SAS HBAs for external SAS JBOD/enclosure 
connectivity support
 
NOTE:  Mixing the Cisco 9300-8e HBA in the same server as the Cisco 12 Gbps 
Modular SAS HBA requires the following firmware levels:
Cisco IMC/BIOS 2.0(8) or later
Cisco UCS Manager 2.2(6) or later (for integrated servers only)