Cisco Cisco ONS 15454 SONET Multiservice Provisioning Platform (MSPP) 故障排查指南

下载
页码 44
and is timing from its own internal clock, the timing source must be within the timing tolerance for a 
minimum of 24 hours. 
Table 1 – Clock Accuracy 
Stratum 
Accuracy 
Adjustment 
Range 
Pull-In-
Range 
Stability 
Time 
To First 
Frame 
Slip  
1 1 x 
10-11 
NA 
NA 
72 days 
2 1.6 x 
10-8 
Must be 
able to 
synchronize 
to clock 
with 
accuracy of 
+/-1.6 x 10-
8 1 x 
10-
10/day  
14 days 
3E 4.6 x 
10-6 
Must be 
able to 
synchronize 
to clock 
with 
accuracy of 
+/-4.6 x 10-
6 1 x 
10-8/day   17 hours 
3 4.6 x 
10-6 
Must be 
able to 
synchronize 
to clock 
with 
accuracy of 
+/-4.6 x 10-
6 3.7 x 
10-7/day  
23 
minutes 
SONET 
Minimum 
Clock 20 
10-6 
Must be 
able to 
synchronize 
to clock 
with 
accuracy of 
+/-20 x 10-
Not 
specified 
Not 
specified 
4E 32 x 
10-6 
Must be 
able to 
synchronize 
to clock 
with 
accuracy of 
+/-32 x 10-
Same as 
Accuracy 
Not 
specified 
Must be 
Page 3 of 44
Cisco - ONS 15454 Timing Issues
12/29/2004
http://www.cisco.com/warp/customer/127/Timing/15454_timingissues.html