Release Notes for Cisco ONS 15454 Release 5.0
OL-5945-01
  Resolved Software Caveats for Release 5.0
Resolved Software Caveats for Release 5.0
This section documents caveats resolved in Release 5.0. Caveats resolved in DWDM Release 4.7 are also 
included.
Maintenance and Administration
DDTS # CSCec57665
When changing the tunnel type from IP Tunnel to a traditional SDCC tunnel, the rollback does not 
restore the original tunnel. If this occurs, manually recreate the tunnel. This issue is resolved in Release 
5.0.
DDTS # CSCuk52184
Rarely, after having completed an ONS 15454 MSTP network installation in which all nodes in the 
network are installed, and Automatic Node setup is provisioned and run, the Optical channel network 
connection provisioning operation does not go to a final state. OCHCH remains in OOS-AINS state. To 
recover from this issue, soft reset all nodes in the affected network. This issue is resolved in Release 5.0.
DDTS # CSCuk52914
Reports of the ports regulated by APC contain some useless ports. The wrong ports are the Channel RX 
ports of MUX, WSS and AD-xC boards. The behavior is common to the CTC and TL1 interfaces. A 
MUX, WSS, or AD-xC board must be present in the system and a circuit be provisioned passing through 
them to see this issue. This issue is resolved in Release 5.0.
DDTS # CSCdy61275
Far end path FC-P is not counted on EC1 or OC3 cards. When a path defect is transmitted to the far end, 
it reports RDI-P. However, the condition is not examined and reported as a PM count. This issue is 
resolved in Release 5.0.
DDTS # CSCef47990
Certain PM values are not displayed in CTC. In particular, if you perform an FC link down and up and 
observe FC LinkRecovery counts, the count will not appear to increase. This issue is resolved in Release 
5.0.
DDTS # CSCef57989
Invalid idles are transmitted in a splitter switch. To see this issue perform the following steps.
Step 1
Set up two MXPP cards connected to each other.
Step 2
Provision the client port as FICON ISL 1G with DE on and Auto detect credit on.
Step 3
Connect the client port to an MDS switch.