PEHA Aura D 20.455.70 FU-BLS 用户手册
产品代码
D 20.455.70 FU-BLS
Cover for flush-mounted receiver
Cover for Easyclick flush-mounted receiver and Easyclick flush-mounted repeater,
other colors available on request.
other colors available on request.
AURA pure white
20.477.02
372613
Easyclick adapter receiver (SCHUKO) Plus, 1 channel (SCHUKO)
Easyclick plug adapter receivers for switching of lights and other electronic consumers
pure white
4511 FU-EP ST
349113
with regard to different settable functions and parameters.
Standard function: 2-pushbutton function.
Selectable functions: 1-pushbutton function, sequential pushbutton function,
staircase lighting function with settable switching off delay and advance OFF warning,
automatic OFF after a settable delay, ventilator control function with delayed ON and
automatic switching off, save and activate 4 light scenarios at the touch of a button
(i.e. for a 4-channel transmitter one light scenario per pushbutton),
ventilator control function with window monitoring.
One function can be specified individually per transmitter once it has been trained.
Connection data: Filament lamp (ohmic load)
Standard function: 2-pushbutton function.
Selectable functions: 1-pushbutton function, sequential pushbutton function,
staircase lighting function with settable switching off delay and advance OFF warning,
automatic OFF after a settable delay, ventilator control function with delayed ON and
automatic switching off, save and activate 4 light scenarios at the touch of a button
(i.e. for a 4-channel transmitter one light scenario per pushbutton),
ventilator control function with window monitoring.
One function can be specified individually per transmitter once it has been trained.
Connection data: Filament lamp (ohmic load)
2500 W
High-voltage halogen lamps 1250W
Electronic ballast
Electronic ballast
3 pieces
IP 20, 230 V, 50 Hz, neutral conductor required. Up to a total of 32 transmitters
can be trained.
can be trained.
Plug adapter version in preparation:
with earthing pin
4571 FU-EP ST
349613
to Swiss standard (SEV) (Schweizerischer Elektrotechnischer Verein)
4571 FU-EP ST CH
349713
in accordance with British norm
4571 FU-EP ST GB
349913
Easyclick adapter dimmer receiver (SCHUKO) Plus, 1 channel (SCHUKO)
Easyclick plug adapter receivers switches and dims lights with regard to different settable
pure white
4511 FU-EP DAB ST
349213
functions and parameters.
This dimmer is controlled by trailing-edge phase cut; it is used with low-voltage halogen
lamps with electronic transformer, filament lamps, high-voltage halogen lamps, and other
ohmic loads.
Standard function: ON/OFF/dimming, 2-pushbutton function with memory.
Selectable functions: ON/OFF/dimming, 2-pushbutton function without memory and
with settable brightness after switching on, ON/OFF defined with 2-pushbutton functions,
UP/DOWN/DIM defined with 2-pushbutton functions, 1-pushbutton function with memory,
staircase lighting with settable switching off time and advance OFF warning, save and
activate 4 light scenarios at the touch of a button (i.e. for a 4-channel transmitter one light
scenario per pushbutton).
One function can be specified individually per transmitter once it has been trained.
The plug adapter has a protection function for unsuited kinds of load and switches OFF
automatically.
Connection data: 60 (minimum ) to 420 (maximum) watts (trailing-edge phase cut),
IP 20, 230 V, 50 Hz, neutral conductor required. Up to a total of 32 transmitters
can be trained.
lamps with electronic transformer, filament lamps, high-voltage halogen lamps, and other
ohmic loads.
Standard function: ON/OFF/dimming, 2-pushbutton function with memory.
Selectable functions: ON/OFF/dimming, 2-pushbutton function without memory and
with settable brightness after switching on, ON/OFF defined with 2-pushbutton functions,
UP/DOWN/DIM defined with 2-pushbutton functions, 1-pushbutton function with memory,
staircase lighting with settable switching off time and advance OFF warning, save and
activate 4 light scenarios at the touch of a button (i.e. for a 4-channel transmitter one light
scenario per pushbutton).
One function can be specified individually per transmitter once it has been trained.
The plug adapter has a protection function for unsuited kinds of load and switches OFF
automatically.
Connection data: 60 (minimum ) to 420 (maximum) watts (trailing-edge phase cut),
IP 20, 230 V, 50 Hz, neutral conductor required. Up to a total of 32 transmitters
can be trained.
Plug adapter version in preparation:
with earthing pin
4571 FU-EP DAB ST
345413
to Swiss standard (SEV) (Schweizerischer Elektrotechnischer Verein)
4571 FU-EP DAB ST CH 345513
in accordance with British norm
4571 FU-EP DAB ST GB
345613
Easyclick flush-mounted ceiling receiver
4-channel switching module, with two pushbuttons, each with ON/OFF function.
454 FU-E DE
380113
30 Easyclick transmitters can be trained to work with one receiver.
Connection options: 3 push-to-make switches and 1 changeover contact (zero-potential
and independently programmable), dimensions: 230 x 55 x 36 mm (LxWxH)
Supply voltage 230 V, 50 Hz, neutral conductor required, screw terminals,
the contacts must not be operated with mixed voltages (i.e. safety extra-low voltage
and 230 V).
Connection data for electrically powered units
per channel:
Connection options: 3 push-to-make switches and 1 changeover contact (zero-potential
and independently programmable), dimensions: 230 x 55 x 36 mm (LxWxH)
Supply voltage 230 V, 50 Hz, neutral conductor required, screw terminals,
the contacts must not be operated with mixed voltages (i.e. safety extra-low voltage
and 230 V).
Connection data for electrically powered units
per channel:
push-to-make (PTM) push-to-break (PTB)
Filament lamp (ohmic load)
2500 W
1000 W
High-voltage halogen lamps
1250 W
500 W
Inductive load
600 VA
250 W
Electronic ballast
3 pieces
1 piece
Article designation
Colour
Article No.
Code No.