Cisco Cisco Virtual Topology System 2.3 發佈版本通知

下载
页码 5
• Support for IPv6— Cisco VTS enables you to deploy tenant networks with IPV6 addresses. Cisco VTS
supports IPv6 for tenant virtual machines for L2 communication.
Limitations and Restrictions
This release has the following limitations / restrictions:
• In an OpenStack Liberty environment, bulk port attach causes errors and multiple VMs fails to spawn
while you try to attach multiple ports to networks. You need to edit the libvirtd.conf file to increase the
keep alive interval. The following configuration is recommended for creation of ten VMs.
# vi /etc/libvirt/libvirtd.conf
keepalive_interval = 5
keepalive_count = 100
• There is a known issue in OpenStack where live migration without shared storage fails after upgrading
to a Kilo version between 2015.1.2-18.1 and 2015.1.3-7. As a workaround, you may need to downgrade
to OpenStack version 2015.1.2-18 or upgrade to OpenStack version 2015.1.3-8. For additional details,
see the following
.
• VTS supports the following versions of OpenStack Kilo:
• 2015.1.0
• 2015.1.1
• 2015.1.2
• 2015.1.3
If you are using an unsupported version, you might encounter errors upon installation. See the Supported
Virtual Machine Managers 
section in the Cisco VTS Installation Guide for more details about supported
VMMs.
• While discovering Cisco ASR 9000 series routers using the Discovery feature, Cisco VTS gets the IP
address of the interface which is connected to the neighbor device (spine or border leaf), and not the
management interface IP address. You need to manually edit the discovery table to provide the
management interface IP address, to ensure that the device is added to the inventory.
• When performing bulk port attach for tenant VMs spawned across multiple hosts with vCenter Web
Client using the networking tab, some of the port attach events are missed and not captured or processed.
Bulk port attach for a maximum of 8 tenant VMs in the same scenario works without any events being
missed. If you need to perform a bulk port attach for more than eight tenant VMs, it would work only
if this is being done for tenant VMs on the same host. This is due to a vCenter networking issue, and a
case has been opened with VMware to resolve this issue
• Do not use special characters while creating Tenant/Network/Router via vCenter VTS plugin. VTS GUI
does not support this, and the name will not show up in the GUI.
• If the IOS XRv registration is incomplete due to an NTP issue, you need to reboot the IOS XRv to
complete the registration process, successfully.
• For V-side tenant VMs, if V2V migrations are performed, you need to perform ARP flush and then ping
the gateway for MAC-to-IP binding to be complete.