Working with a Failed Array
Linksys Small Business NSS4000 and NSS6000 Series Network Storage System Administration Guide
160
A
The RAID Configuration page appears.
STEP 4
Available disk drives appear in the listing. Click Add to add the disk drive to 
the array. 
The RAID array is rebuilt for the added or changed redundant disk drive. While 
the rebuild continues, the array can still be used. After the rebuild process 
completes, the disk becomes part of the redundant storage. You can monitor 
the progress of the rebuild through the System Status page.
Working with a Failed Array
If a RAID is in a failed state, the data on the array is not recoverable. You need to 
delete the array, replace the disk drive, and then configure a new array. 
To create an array when an array fails:
STEP 1
Remove the failed drive from the NSS and install the replacement disk. (This step 
can be done out of order as long as it is installed before you configure the new 
array.) 
STEP 2
Reboot the NSS. Make sure that you do a safe reboot using the Reboot function. 
See 
STEP 3