Fujifilm FCR PROFECT ONE (Computed Radiography) 产品宣传页
F U J I C O M P U T E D R A D I O G R A P H Y
FUJIFILM FCR PROFECT ONE Specifications
IP Cassette with Imaging Plate
Mammography QC Program
740 (29)
655 (26)
1330 (52)
Standard Components:
• FCR PROFECT ONE Image Reader (Model: CR-IR 368)
• AC power cord
• FCR PROFECT ONE Image Reader (Model: CR-IR 368)
• AC power cord
Other System Components (sold separately):
• CR Console Plus, MAMMOASCENT AWS-c
• Image Recorder : DRYPIX 4000 / 7000
• ID Card Writer
• FCR Data Management System
• CR Console Plus, MAMMOASCENT AWS-c
• Image Recorder : DRYPIX 4000 / 7000
• ID Card Writer
• FCR Data Management System
Supplies:
Imaging Plate:
• ST-VI (Standard): 14”
Imaging Plate:
• ST-VI (Standard): 14”
✕
17”, 14”
✕
14”, 10”
✕
12”, 8”
✕
10”, 24
✕
30 cm, 18
✕
24 cm
• HR-V (High Resolution): 24
✕
30 cm, 18
✕
24 cm
• ST-BD (Standard Dual-Side Imaging): 24
✕
30 cm, 18
✕
24 cm
• HR-BD (Dual-Side Mammography): 24
✕
30 cm, 18
✕
24 cm
IP Cassette:
• Type CC: 14”
• Type CC: 14”
✕
17”, 14”
✕
14”, 10”
✕
12”, 8”
✕
10”, 24
✕
30 cm, 18
✕
24 cm
• Type CH: 24
✕
30 cm, 18
✕
24 cm
• Type DS: 24
✕
30 cm, 18
✕
24 cm
• Type DM: 24
✕
30 cm, 18
✕
24 cm
• Type LC: 35.4
✕
124.5cm, 35.4
✕
101.7cm, 35.4
✕
83.0cm, 25.2
✕
58.0cm, 24.0
✕
57.0cm
Dimensions (W
✕
D
✕
H): 655
✕
740
✕
1330 mm (26”
✕
29”
✕
52”)
Weight: 230 kg (507 lbs.)
Power Supply Conditions:
Single phase 50-60Hz
AC120-240V
Single phase 50-60Hz
AC120-240V
±
10%
7A (max)
Environmental Conditions:
• Operating Conditions:
• Operating Conditions:
Temperature: 15-30
°
C
Humidity: 40-80%RH (No dew condensation)
• Non-operating Conditions:
Temperature: 0-45
°
C
Humidity: 10-90%RH (No dew condensation)
Number of Stackers: 1
Reading Gray Scale: 12 bits
Network: 10 Base T/100 Base TX
Time to Print on DRYPIX 7000 (18
✕
24 HR-BD & ST-BD) :
Approx. 140 sec.
Processing Capacity
(in high-pixel density two-image output format):
(in high-pixel density two-image output format):
Image Reading (Image output is via CR Console)
Standard Pixel-density
High Pixel-density
Reading Size
14”
✕
17” (35
✕
43 cm)
14”
✕
14” (35
✕
35 cm)
10”
✕
12”
8”
✕
10”
24
✕
30 cm (ST-VI & HR-V)
18
✕
24 cm (ST-VI & HR-V)
24
✕
30 cm (ST-BD & HR-BD)
18
✕
24 cm (ST-BD & HR-BD)
5
5
6.7
10
6.7
10
10
10
1760
✕
2140
1760
✕
1760
1670
✕
2010
2000
✕
2510
1576
✕
1976
1770
✕
2370
2364
✕
2964
1770
✕
2370
10
10
10
10
10
10
20
20
3520
✕
4280
3520
✕
3520
2505
✕
3015
2000
✕
2510
2364
✕
2964
1770
✕
2370
4728
✕
5928
3540
✕
4740
IP Type
When connected to
DRYPIX 7000/CR Console Plus
ST-BD
ST-BD
HR-BD
HR-BD
IP Size
24
✕
30 cm
18
✕
24 cm
24
✕
30 cm
18
✕
24 cm
Approx. 42 IPs/hr.
Approx. 48 IPs/hr.
Approx. 40 IPs/hr.
Approx. 45 IPs/hr.
A state-of-the-art single-stacker FCR Reader for
mammography and pediatric images in high resolution.
mammography and pediatric images in high resolution.
IP Type
ST-VI
ST-VI
ST-VI
ST-VI
ST-VI
ST-VI
HR-V
HR-V
ST-BD
ST-BD
HR-BD
HR-BD
IP Size
14”
✕
17” (35
✕
43 cm)
14”
✕
14” (35
✕
35 cm)
10”
✕
12”
8”
✕
10”
24
✕
30 cm
18
✕
24 cm
24
✕
30 cm
18
✕
24 cm
24
✕
30 cm
18
✕
24 cm
24
✕
30 cm
18
✕
24 cm
Required Time
Approx. 60 sec.
Approx. 54 sec.
Approx. 50 sec.
Approx. 40 sec.
Approx. 51 sec.
Approx. 42 sec.
Approx. 65 sec.
Approx. 55 sec.
Approx. 85 sec.
Approx. 75 sec.
Approx. 90 sec.
Approx. 80 sec.
DM Cassette with IP HR-BD for
Dual-Side Mammography
Dual-Side Mammography
DS Cassette with IP ST-BD for
Standard Dual-Side imaging
Standard Dual-Side imaging
Fujifilm’s Mammography QC Program
is a dedicated quality control program
applicable to FUJIFILM digital
mammography systems. This program
enables the system to keep a stable
image quality for both screening and
diagnosis.
is a dedicated quality control program
applicable to FUJIFILM digital
mammography systems. This program
enables the system to keep a stable
image quality for both screening and
diagnosis.
This equipment is a Class 1 laser product (IEC60825).
Specifications are subject to change without notice.
All brand names or trademarks are the property of their respective owners.
In some countries, regulatory approval may be required to import medical devices.
For the availability of these products, please contact your local sales representatives.
All brand names or trademarks are the property of their respective owners.
In some countries, regulatory approval may be required to import medical devices.
For the availability of these products, please contact your local sales representatives.
FUJIFILM supports
the Pink Ribbon Campaign for
early detection of breast cancer
the Pink Ribbon Campaign for
early detection of breast cancer
Ref. No. XB-972E
(SK·09·11·F1120·F9711) Printed in Japan ©2009 FUJIFILM Corporation
26-30, NISHIAZABU 2-CHOME, MINATO-KU, TOKYO 106-8620, JAPAN
http://www.fujifilm.com/products/medical/
Number of Pixels
Pixels/mm
Number of Pixels
Pixels/mm
Dimensions
Unit: mm (in.)
http://www.fujifilm.com/products/medical/
*1:
PMA (Premarket Approval) *2:
FDA (U.S. Food and Drug Administration)
FCR, the world’s first CR to receive PMA
*1
approval from FDA
*2
for mammography.
Type DM
Type DS
Time Required for IP Feed/Load: