Cisco Compact Broadband Amplifier 93218 and 93228 数据表

下载
页码 6
Compact EGC Amplifier Model 93251 
 
4
 
Specifications
, continued
 
General Performance 
Units 
Description 
Notes
SMC/HMS Receive Level Attenuation 
dB 
-33 
± 0.75
 
 
SMC/HMS Transmit Insertion Loss 
dB 
-20 
± 0.75 
 
Surge Protection 
kV, µs
6, 1.2/50 
Enclosure Category 
– 
IP 66 
 
Emission, EN 50083-2 
dBpW 
< 20 
 
Screening dB 
85 
 
Connectors, Inputs and Outputs(reduction) 
– 
PG 11 (5/8’’) 
 
Test Point 
– 
F-connector, Female 
 
Electrical 
 
 
 
65 V COAX Line Powering (rms, sine) 
V AC 
24 to 65 
 
230 V Mains Line Powering (rms, sine) 
V AC 
187 to 250 
 
Power Consumption, network powered 
25.5 with built-in reverse amp 
27.5 with plug-in transponder 
 
Current Draw 
A AC 
See table  
10 
Max. Current, Inputs and Outputs 
A AC 
8 
 
Max. Current, Local Input 
A AC 
15 
 
Hum Modulation 
dB 
≤ -65  
 
Compliance/Safety 
 
 
 
Electrical Safety 
– 
EN 50083-1 
EN 60065  
IEC 65 
 
EMC Emissions 
– 
EN 50083-2 
 
Environmental 
 
 
 
Operating Temperature Range 
°C 
°F 
-20 to +55 
-4 to +131 
 
Mechanical 
 
 
 
Housing Dimensions (W x H x D) 
mm 
in. 
230 x 155 x 95 
9.1 x 6.1 x 3.7 
 
Packaging Dimensions (W x H x D) 
mm 
in. 
270 x 285 x 100 
10.6 x 11.2 x 3.8 
 
Weight 
kg 
lbs 
2.7 
6.0 
 
Notes: 
1. 
Frequency range depends on plug-in diplex filters and amplifier settings. 
2. 
With diplex filters. 
3. 
Two outputs that can be activated by using splitter or directional coupler. 
4. 
At 40 MHz red. 1.5 dB/octave. 
5. 
Maximum gain, no equalization. 
6. 
With 6 dB interstage EQ 
7. 
Change in CTB, CSO, and Noise Figure with different interstage attenuation, relative to 0 dB. 
40 dB 
CTB 
CSO 
Noise Figure
2 dB 
0.1 
4 dB 
0.2 
6 dB 
0.3 
34 dB
 
CTB
 
CSO
 
Noise Figure
2 dB 
0.1 
4 dB 
0.2 
6 dB 
0.3 
28 dB
 
CTB
 
CSO
 
Noise Figure
2 dB 
0.2 
4 dB 
0.6 
6 dB 
1.0 
8. 
Start from 7 MHz. 
9. 
According to IEC60 on input and output with diplex filters.  
10.  AC current draw is tested with 50 meters coaxial cable.