Acting Upon the Daily DMP Health Report
§
Non-compliant DMPs:
• If you know that you normally have a certain number of DMPs in non-compliant state, then
ignore this entry.
• If the number of non-compliant DMPs is not what you expect, investigate and correct the
issue(s).
§
If you see that an unusual number of DMPs have recently rebooted, investigate
further. This could be due to a power fluctuation issue in the edge switch, the edge
switch itself was rebooted, or another issue caused a break in power supply to the
affected DMPs.
further. This could be due to a power fluctuation issue in the edge switch, the edge
switch itself was rebooted, or another issue caused a break in power supply to the
affected DMPs.
§
What really counts is the ‘Devices in critical state’ and ‘Devices not reachable’
entries!
entries!
• These reported numbers are typically equal, but not necessarily so. For example, Flash
Template corruption or missing Flash Template will show up as “critical” but not
“unreachable”.
“unreachable”.
• Investigate the affected DMPs and replace if necessary!
• Do not simply ignore these DMPs as 99.99% of the time their TV screens will be all black!
§
It is recommended that you inform your Event Manager (EM) about these DMPs
and resolve all DMPs to green state, replacing any DMPs as necessary.