Cisco Cisco Content Security Management Appliance M390 發佈版本通知

下载
页码 16
 
14
Release Notes for Cisco IronPort AsyncOS 7.9.0 for Security Management
  Known Issues
Known Issues
Note
Known issues in AsyncOS for Email Security and AsyncOS for Web are documented in the release notes 
for those products. 
71976
Fixed: (M160 Hardware only) Disk fails with RAID alert 
Software RAID robustness has been improved, making these disk failures less likely to occur.
Table 9
Known Issues for Release 7.9  
Defect ID
Description
86777
Importing a Web Security appliance configuration file to Configuration Master 7.5 may fail 
Importing a configuration file saved from AsyncOS 7.5.0-727 gives the following error: "Web Configuration 
File was not imported. Parse Error on element "wccp_debug_level" line number 4335 column 23 with value 
"5": Value must be an integer from 0 to 4."
Workaround: Manually update the "wccp_debug_level" from "5" to "4".  Save the configuration file and 
import the changed file. 
84881 
Application fault occurs if centralized reporting is enabled but zero disk space is allocated for 
centralized reporting 
The following application fault occurs if centralized reporting is enabled but zero disk space is allocated for 
centralized reporting: 'No such file or directory...'.
To prevent this issue: Before you enable centralized email and/or web reporting, go to System 
Administration > Disk Management and ensure that at least 1 GB of disk space has been allocated for 
Centralized Reporting. 
To recover from this issue: Allocate disk space as described above, then reboot the appliance. 
85059
Error when importing a configuration file to a Configuration Master or using Advanced File Publish 
This error occurs when managing Web Security appliances running AsyncOS 7.5.0. 
Importing a configuration file from AsyncOS 7.5.0 to a Configuration Master, or publishing a configuration 
to AsyncOS 7.5.0 using Advanced File Publish, will fail with the following error: 
"Failure: ERROR: Element 'prox_etc_send_size' not allowed here at Unknown:3272:25 Text: 
262144"
 
Workaround: Upgrade your Web Security appliance to a build later than 7.5.0-703. The build number 
appears in the Upgrade Paths section of the Release Notes for each release. 
84778
Issue Priority options on “Open a Technical Support Case” page are not translated 
On the “Open a Technical Support Case” page under the Help and Support menu, the options for Issue 
Priority do not appear in the language currently selected in Preferences. 
Table 8
Resolved Issues in Cisco IronPort AsyncOS 7.7 for Security Management  (continued)
Defect ID
Description