Cisco Cisco UCS C3160 Rack Server 白皮書

下载
页码 51
7   © 2016 Cisco and/or its affiliates. All rights reserved.
This detailed architecture for the Cisco UCS with SvSAN deployment consists of the components listed in Table 2.
Table 2. Cisco UCS with StorMagic SvSAN Deployment Components
Component
Description
Cisco UCS
2 x Cisco UCS C240 M4 Rack Servers (x86 servers), each with:
• 2 x Intel Xeon processor E5-2660 v3 CPUs
• 16 x 16-GB DDR4 2133-MHz RDIMM (PC4-17000) dual rank x4 1.2V memory
• 8 x Seagate 1.2-TB 6.0-Gbs 10,000-rpm SAS HDDs
• Embedded (onboard) Intel I350 1-Gbps network controller, with 2 ports
•  1 x Cisco 12G SAS Modular Raid Controller with 2-GB flash-based write cache (FBWC)  
(UCSC-MRAID12G-2GB)
• 1 x Cisco UCS VIC 1227 10-Gbps dual-port CNA SFP+ (UCSC-MLOM-CSC-02)
• 2 x 32-GB FlexFlash cards (UCS-SD-32G-S)
VMware software
• VMware vCenter 6.0.0b
• VMware ESXi 6.0.0b
StorMagic SvSAN software
Release 5.3
Note: New software and firmware releases should be installed as listed in the Cisco UCS Hardware and Software 
Interoperability Matrix at 
 For information about the 
StorMagic SvSAN certified and supported versions, see the VMware Hardware Compatibility List (HCL) at 
Table 3 lists the virtual machine sizing assumptions used for the Cisco UCS with SvSAN deployment. 
Table 3.  Virtual Machine Configuration
Virtual machine instance size
• 4 virtual CPUs (vCPUs) with 6 GB of RAM
• 50-GB OS logical unit number (LUN) and 100-GB raw LUN for I/O test