Cisco Cisco Firepower Management Center 4000 开发者指南

下载
页码 536
 
B-67
FireSIGHT eStreamer Integration Guide
 
Appendix B      Understanding Legacy Data Structures
  Legacy Discovery Data Structures
String Block 
Length
uint32
Number of bytes in the minor String data block, including eight bytes 
for the block type and length fields, plus the number of bytes in the 
version.
Minor Version
string
Minor version number of the Cisco 3D operating system definition 
that a third party operating system string in the user input is mapped 
to. 
String Block 
Type
uint32
Initiates a String data block containing the revision number of the 
Cisco operating system definition that a third party operating system 
string in the user input is mapped to. This value is always 
0
.
String Block 
Length
uint32
Number of bytes in the revision String data block, including eight 
bytes for the block type and length fields, plus the number of bytes in 
the revision number.
Revision
string
Revision number of the Cisco 3D operating system definition that a 
third party operating system string in the user input is mapped to. 
String Block 
Type
uint32
Initiates a String data block containing the last major version of the 
Cisco 3D operating system definition that a third party operating 
system string is mapped to. This value is always 
0
.
String Block 
Length
uint32
Number of bytes in the To Major String data block, including eight 
bytes for the block type and length fields, plus the number of bytes in 
the version.
To  Major
string
Last version number in a range of major version numbers of the Cisco 
3D operating system definition that a third party operating system 
string in the user input is mapped to.
String Block 
Type
uint32
Initiates a String data block containing the last minor version of the 
Cisco 3D operating system definition that a third party operating 
system string is mapped to. This value is always 
0
.
String Block 
Length
uint32
Number of bytes in the To Minor String data block, including eight 
bytes for the block type and length fields, plus the number of bytes in 
the version.
To  Minor
string
Last version number in a range of minor version numbers of the Cisco 
3D operating system definition that a third party operating system 
string in the user input is mapped to.
String Block 
Type
uint32
Initiates a String data block containing the Last revision number of 
the Cisco 3D operating system definition that a third party operating 
system string is mapped to. This value is always 
0
.
String Block 
Length
uint32
Number of bytes in the To Revision String data block, including eight 
bytes for the block type and length fields, plus the number of bytes in 
the revision number.
To Revision
string
Last revision number in a range of revision numbers of the Cisco 3D 
operating system definitions that a third party operating system string 
in the user input is mapped to.
String Block 
Type
uint32
Initiates a String data block containing the build number of the Cisco 
3D operating system that the third party operating system string is 
mapped. This value is always 
0
.
Table B-15
User Product Data Block Fields for 4.10.x, 5.0-5.0.x (continued)
Field
Data Type
Description