Cisco Cisco Content Security Management Appliance M1070 用户指南
14-34
AsyncOS 9.0 for Cisco Content Security Management Appliances User Guide
Chapter 14 Common Administrative Tasks
Managing Alerts
MAIL.RES_CON_START_
ALERT
ALERT
Sent when the appliance enters “resource conservation”
mode.
mode.
Critical
MAIL.RES_CON_STOP_
ALERT
ALERT
Sent when the appliance leaves “resource conservation”
mode.
mode.
Critical
MAIL.WORK_QUEUE_
PAUSED_NATURAL
PAUSED_NATURAL
Sent when the work queue is paused.
Critical
MAIL.WORK_QUEUE_
UNPAUSED_NATURAL
UNPAUSED_NATURAL
Sent when the work queue is resumed.
Critical
NTP.NOT_ROOT
Sent when the appliance is unable to adjust time because
NTP is not running as root.
NTP is not running as root.
Warning
PERIODIC_REPORTS.
DOMAIN_REPORT.
DOMAIN_FILE_ERRORS
DOMAIN_REPORT.
DOMAIN_FILE_ERRORS
Sent when errors are found in the domain specification
file.
file.
Critical
PERIODIC_REPORTS.
DOMAIN_REPORT.FILE_
EMPTY
DOMAIN_REPORT.FILE_
EMPTY
Sent when the domain specification file is empty.
Critical
PERIODIC_REPORTS.
DOMAIN_REPORT.FILE_
MISSING
DOMAIN_REPORT.FILE_
MISSING
Sent when the domain specification file is not found.
Critical
REPORTD.DATABASE_
OPEN_FAILED_ALERT
OPEN_FAILED_ALERT
Sent if the reporting engine is unable to open the
database.
database.
Critical
REPORTD.AGGREGATION_D
ISABLED_ALERT
ISABLED_ALERT
Sent if the system runs out of disk space. When the disk
usage for a log entry exceeds the log usage threshold,
reportd disables aggregation and sends the alert.
usage for a log entry exceeds the log usage threshold,
reportd disables aggregation and sends the alert.
Warning
REPORTING.CLIENT.
UPDATE_FAILED_ALERT
UPDATE_FAILED_ALERT
Sent if the reporting engine was unable to save reporting
data.
data.
Warning
REPORTING.CLIENT.
JOURNAL.FULL
JOURNAL.FULL
Sent if the reporting engine is unable to store new data.
Critical
REPORTING.CLIENT.
JOURNAL.FREE
JOURNAL.FREE
Sent when the reporting engine is again able to store new
data.
data.
Information
PERIODIC_REPORTS.
REPORT_TASK.BUILD_
FAILURE_ALERT
REPORT_TASK.BUILD_
FAILURE_ALERT
Sent when the reporting engine is unable to build a report. Critical
PERIODIC_REPORTS.
REPORT_TASK.EMAIL_
FAILURE_ALERT
REPORT_TASK.EMAIL_
FAILURE_ALERT
Sent when a report could not be emailed.
Critical
PERIODIC_REPORTS.
REPORT_TASK.ARCHIVE_FA
ILURE_ALERT
REPORT_TASK.ARCHIVE_FA
ILURE_ALERT
Sent when a report could not be archived.
Critical
SENDERBASE.ERROR
Sent when an error occurred while processing a response
from SenderBase.
from SenderBase.
Information
SMAD.ICCM.ALERT_PUSH_
FAILED
FAILED
Sent if a configuration push failed for one or more hosts. Warning
SMAD.TRANSFER.
TRANSFERS_STALLED
TRANSFERS_STALLED
Sent if SMA logs are unable to fetch tracking data for two
hours or reporting data for six hours.
hours or reporting data for six hours.
Warning
Alert Name
Description
Severity