Cisco Cisco IOS XE 3.5E 發佈版本通知
37
Release Notes for the Catalyst 4500-X Series Switches, Cisco IOS XE Release 3.8.xE
Limitations and Restrictions
Workaround: None. CSCua87538
•
An incorrect module number is displayed in the console messages during boot up of a Cat4500X
VSS.
VSS.
*Jul 18 12:36:11.138: %C4K_IOSMODPORTMAN-6-MODULEONLINE: Module 11 (WS-C4500X-32
S/N: JAE154503I8 Hw: 1.0) is online
Because the Catalyst 4500-X is a “fixed” configuration device, in a VSS, you would expect the two
systems to be labeled 'Module 1' and 'Module 2.’ However, because of software implementation
similarities with the modular Catalyst 4500E series switches, the Standby switch is labeled 'Module
11.’
systems to be labeled 'Module 1' and 'Module 2.’ However, because of software implementation
similarities with the modular Catalyst 4500E series switches, the Standby switch is labeled 'Module
11.’
Workaround: None. CSCub11632
•
Memory allocation failures can occur if more than 16K IPv6 multicast snooping entries are present.
Workaround: None. CSCuc77376
•
Beginning with IOS Release XE 3.5.0E, error messages that occur when a QoS policy is applied will
no longer appear directly on the console when no logging console is configured. They will appear
only when a logging method is active (e.g., logging buffered, logging console, …).
no longer appear directly on the console when no logging console is configured. They will appear
only when a logging method is active (e.g., logging buffered, logging console, …).
Workaround: None. CSCuf86375
•
Setting a cos value based on QoS group triggers the following error message in a VSS system
set action fail = 9
Workaround: None. QoS groups are not supported in VSS. CSCuc84739
•
Auto negotiation cannot be disabled on the Fa1 port. It must be set to auto/auto, or fixed speed with
duplex auto.
duplex auto.
•
The following messages are seen during boot up after POST check.
Rommon reg: 0x00004F80
Reset2Reg: 0x00000F00
Image load status: 0x00000000
#####
Snowtrooper 220 controller 0x0430006E..0x044E161D Size:0x0057B4C5 Program Done!
#########################
[ 6642.974087] pci 0000:00:00.0: ignoring class b20 (doesn't match header type 01)
Starting System Services
Calculating module dependencies ...
Loading rtc-ds1307
RTNETLINK answers: Invalid argument
No Mountpoints DefinedJan 17 09:48:14 %IOSXE-3-PLATFORM: process sshd[5241]: error:
Bind to port
22 on :: failed: Address already in use
Starting IOS Services
Loading virtuclock as vuclock
Loading gsbu64atomic as gdb64atomic
/dev/fd/12: line 267: /sys/devices/system/edac/mc/edac_mc_log_ce: No such file or
directory
Aug 8 20:30:29 %IOSXE-3-PLATFORM: process kernel: mmc0: Got command interrupt
0x00030000 even though no command operation was in progress.
Aug 8 20:30:29 %IOSXE-3-PLATFORM: process kernel: PME2: fsl_pme2_db_init: not on
ctrl-plane
These messages are cosmetic only, and no ssh services are available unless configured within IOS.
Workaround: None CSCue15724