Cisco Cisco Broadband Access Center for Cable 2.7 發佈版本通知

下载
页码 22
 
9
Release Notes for Broadband Access Center for Cable 2.7
78-15814-03 
    Known Software Problems
CSCeh03452
The syntax used in 
conjunction with the 
runCfgUtil.sh tool does not 
allow a way to generate 
options where it could have 
nested sub-options. 
When using DOCSIS 2.0 for 
example:
41.
41.1 
41.1.1 30 
41.1.2 10000000 
41.1 41.1.1 30
41.1.2 20000000 
41. 41.2 
41.2.1 30
41.2.2 30000000 
The only workaround to this 
problem is to break multiple 
suboptions into multiple 
groups.
According to the DOCSIS 2.0 
RF spec, this definition 
achieves the same result:
41. 
41.1 
41.1.1 30 
41.1.2 10000000
41. 
41.1 
41.1.1 30 
41.1.2 20000000
41. 
41.2 
41.2.1 30 
41.2.2 30000000 
CSCeh25095
You cannot upgrade the DPE 
or Network Registrar 
Extension Points by using the 
setup.bin package. However, 
if you attempt to do this, there 
is no error message to 
specifically indicate this 
restriction.
Use the upgrade scripts 
supplied with BACC to 
upgrade these components.
Table 1
BACC Known Software Problems (continued)
Number
Description
Resolution