Cisco Cisco Transport Manager 9.1 技术参考
MTNM IMPLEMENTATION STATEMENT TEMPLATES AND GUIDELINES
TMF 814Av3.0
TeleManagement Forum 2003
13
Table 2-8. Notifications for Second-Level Objects
Notification
Type
Type
Notification Producers
Variations from the MTNM Interface
Specification
Specification
Object
Creation
Creation
Topological Link, Equipment, Equipment Holder,
Subnetwork, Traffic Descriptor, PTP, TP Pool,
Subnetwork Connection, Managed Element,
Protection Group
Subnetwork, Traffic Descriptor, PTP, TP Pool,
Subnetwork Connection, Managed Element,
Protection Group
(v3.0) ASAP, Equipment Protection Group, Group
Termination Point, Log, Transmission Descriptor
Termination Point, Log, Transmission Descriptor
Object
Deletion
Deletion
Topological Link, Equipment, Equipment Holder,
Subnetwork, Traffic Descriptor, PTP, TP Pool,
Subnetwork Connection, Managed Element,
Protection Group
Subnetwork, Traffic Descriptor, PTP, TP Pool,
Subnetwork Connection, Managed Element,
Protection Group
(v3.0) ASAP, Equipment Protection Group, Group
Termination Point, Log, Transmission Descriptor
Termination Point, Log, Transmission Descriptor
Attribute Value
Change (AVC)
Change (AVC)
Topological Link, Equipment, Equipment Holder,
Subnetwork, Traffic Descriptor, PTP, CTP, TP
Pool, Subnetwork Connection, Managed Element,
Protection Group, EMS
Subnetwork, Traffic Descriptor, PTP, CTP, TP
Pool, Subnetwork Connection, Managed Element,
Protection Group, EMS
(v3.0) ASAP, Equipment Protection Group, Group
Termination Point, Log, Transmission Descriptor
Termination Point, Log, Transmission Descriptor
State Change
Equipment Holder, Equipment, PTP, CTP,
Subnetwork Connection, Managed Element,
Protection Group
Subnetwork Connection, Managed Element,
Protection Group
(v3.0) Equipment Protection Group, Group
Termination Point, Log
Termination Point, Log
2.2 Alarm Severity Assignment Profile (v3.0)
2.2.1 Data Types
Table 2-9. ASAP
Attribute Name
Set
By
Set When and How
Format
Clarification Needed
name EMS
C
FREE
userLabel
E
A – set by the EMS (C),
or by the NMS via
createASAP (C) or
setUserLabel (L)
or by the NMS via
createASAP (C) or
setUserLabel (L)
FREE
nativeEMSName
E
A – set by the EMS (C),
or by the NMS via
createASAP (C) or
setNativeEMSName (L)
or by the NMS via
createASAP (C) or
setNativeEMSName (L)
FREE (e.g. CLEI
code)
owner
NMS
L – setOwner
FREE
As noted in Section
4.3, userLabel, owner,
nativeEMSName can
be used in a variety of
ways. The EMS
vendor (SP) should
describe their
particular usage of
these attributes.
4.3, userLabel, owner,
nativeEMSName can
be used in a variety of
ways. The EMS
vendor (SP) should
describe their
particular usage of
these attributes.
fixed EMS
C
FIXED
alarmSeverityAssignmentList
E
A – set by the EMS (C),
or by the NMS via
createASAP (C) or
modifyASAP (L)
or by the NMS via
createASAP (C) or
modifyASAP (L)
FREE
EMS supplier should
indicate range of
possible value
indicate range of
possible value