Cisco Cisco Prime Optical 9.8 开发者指南
Cisco Prime Optical 9.8 GateWay/CORBA Programmer Reference Guide
OL-29218-01
210
• globaldefs::NVSList_T additionalInfo
Supported. Three parameters are sent in this field:
– A name/value pair for the IP address with the name “IPAddress.”
– A name/value pair for the operational state with the name “OperationalState,” containing the
– A name/value pair for the operational state with the name “OperationalState,” containing the
following values. The emsInSyncState value is determined by the OperationalState value. A
state change event is generated whenever the state of emsInSyncState changes.
state change event is generated whenever the state of emsInSyncState changes.
OperationStates
EmsInSyncState
PreProvisioned
False
InServiceSyncConfiguration
False
OutOfService
False
UnderMaintenance
False
InServiceIntializing
False
InService
True
– A name/value pair for the vendor with the name “VendorName.”
In addtion to the preceding, the following parameters are available for a restricted group of
MEs:
MEs:
• A name/value pair for the ME Description field with the name “Description.” It is an
editable, free text field. When modified, AVC notifications are not sent to GateWay/CORBA
clients.
clients.
• A name/value pair for the ME Latitude field with the name “Latitude.” It is an editable field
in the format “North/South <num> Deg <num> Min” (for example, “North 38 Deg 13 Min”).
When modified, AVC notifications are not sent to GateWay/CORBA clients.
When modified, AVC notifications are not sent to GateWay/CORBA clients.
• A name/value pair for the ME Longitude field with the name “Longitude.” It is an editable
field in the format “West/East <num> Deg <num> Min” (for example, “West 122 Deg 38
Min”). When modified, AVC notifications are not sent to GateWay/CORBA clients.
Min”). When modified, AVC notifications are not sent to GateWay/CORBA clients.
The following table lists the MEs that support these additional parameters:
Attribute Name
Supporting ME
Description
Latitude
Longitude
These attributes are read-only in
GateWay/CORBA. You must use the Prime
Optical client to edit them.
Optical client to edit them.
15454
15454 SDH
CPT 200
CPT 200 SDH
CPT 600
CPT 600 SDH
ONS 15305 CTC
ONS 15310 CL