MTNM IMPLEMENTATION STATEMENT TEMPLATES AND GUIDELINES  
intervalStatus EMS  C  FIXED 
 
 
 
Table Error! No text of specified style in document.-51. PMThresholdValue 
Attribute Name 
Set 
By 
Set When and How 
Format 
Clarification Needed 
pmParameterName 
EMS 
VALUE LIST 
The EMS vendor (SP) 
should indicate the PM 
parameter for which they 
support (require) 
thresholding.  
pmLocation EMS 
FIXED 
 
thresholdType 
EMS 
FIXED 
For each type of 
thresholdable PM 
parameter, the EMS 
vendor (SP) should 
indicate the type of 
TRIGGER supported 
(required) and whether or 
not there is an associated 
CLEAR.  
value EMS 
FIXED 
 
unit EMS 
FREE 
 
 
 
Table Error! No text of specified style in document.-52. PMP (v3.0) 
Attribute Name 
Set 
By 
Set When and How 
Format 
Clarification Needed 
name EMS C 
FREE 
 
userLabel 
A – set by the EMS (C), or 
by the NMS via 
setUserLabel (L) 
FREE 
nativeEMSName 
A – set by the EMS (C), or 
by the NMS via 
setNativeEMSName (L) 
FREE (e.g. CLEI 
code) 
owner 
NMS 
L – setOwner  
FREE 
As noted in Section 4.3, 
userLabel, owner, 
nativeEMSName can be 
used in a variety of ways. 
The EMS vendor (SP) 
should describe their 
particular usage of these 
attributes. 
pmParameterWith 
ThresholdsList 
EMS C 
VALUE 
LIST 
 
monitoringState 
A – set by the EMS (A), or 
by the NMS via 
enablePMData or 
disablePMData (L) 
FIXED  
supervisionState 
A – set by the EMS (A), or 
by the NMS via enableTCA 
or disableTCA (L) 
FIXED  
additionalInfo 
A – set by EMS (C), or by 
the NMS via 
setAdditionalInfo 
FREE 
Name/Value list defined by 
the EMS vendor 
TMF814Av3.1 
TeleManagement Forum 2007 