Cisco Cisco 1 GHz GainStar Node 安装指南

下载
页码 73
 
Balancing and Setup 
 
 
 
36 
 
2  Measure the output level, and compare this level with the design level. The test 
point attenuates output signals by 20 dB. 
3  Is the measured output level within ± 0.5 dB of the design level? 
 
If yes, proceed to step 5.   
 
If the output level is more than the design output level, replace the reverse 
output pad with a higher value pad.   
 
If the output level is less than the design level, replace the reverse output pad 
with a lower value pad. 
4  Repeat steps 2 and 3 until the output level is correct. 
5  Remove the test probe from the reverse output test point, leaving other 
equipment connectors intact. 
To Set Up the Equalizer Values for Reverse Path 
85 MHz Platform 
The reverse output tilt can be adjusted using the Reverse Equalizer (EQ). Each EQ 
has a range of values. The EQ value is set by installing the corresponding attenuator 
pad. There are two types of reverse EQs for the 85 MHz Platform: 0 dB to 5 dB, P/N 
GS-REQ-85-00-05; 6 dB to 10 dB, P/N GS-REQ-85-06-10. See the table below for the 
full range of configurations for the 85 MHz Platform EQs. 
* The section in gray indicates factory default value. 
Reverse 
Equalization 
Reverse Equalizer 
Pad for Reverse Equalizer 
Description  PN 
Description 
PN 
0 dB * 
GS Rev 
Cable EQ, 
0 to 5 dB 85 
MHz 
Platform 
 
GS-REQ-
85-00-05, 
0 to 5 dB 
0 dB 1 GHz Plug-In Attenuator    4036021 
1 dB 
1 dB 1 GHz Plug-In Attenuator    4036022 
2 dB 
2 dB 1 GHz Plug-In Attenuator    4036023 
3 dB 
3 dB 1 GHz Plug-In Attenuator    4036024 
4 dB 
4 dB 1 GHz Plug-In Attenuator    4036025 
5 dB 
5 dB 1 GHz Plug-In Attenuator    4036026 
6 dB 
GS Rev 
Cable EQ, 6 
to 10 dB 85 
MHz 
Platform 
 
GS-REQ
-85-06-1
0, 6 to 
10 dB 
6 dB 1 GHz Plug-In Attenuator    4036027 
7 dB 
7 dB 1 GHz Plug-In Attenuator    4036028 
8 dB 
8 dB 1 GHz Plug-In Attenuator    4036029 
9 dB 
9 dB 1 GHz Plug-In Attenuator    4036030 
10 dB 
10 dB 1 GHz Plug-In Attenuator    4036031