Cisco Cisco Live Event Controller 数据表
© 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 2 of 4
Data Sheet
Specifications
Table 1.
Product Specifications
Feature
Description
Conditional Access
Brand
PowerVu CA
Crypto Cycle
>= 1 sec
Services
85
Management
Control System
Integrated in PNC
Inputs/Outputs
Number of ports
Port 1 is for Simulcrypt communications
Ports 2, 3, and 4 are unused
Type
Eight-pin RJ-45, MDI
Ethernet type
100/1000BASE-T
Format
Simulcrypt Protocols
Environment/Physical
Dimensions
1.73 in. H x 21.42 in. W x 17.36 in. D (4.4 cm H x 54.4 cm W x 44.1 cm D)
1U high, 19 in. rack mountable, stackable
Operating temperature
0
– 50°C (32 – 122°F)
Storage temperature range
-10
– 70°C (14 – 158°F)
Weight
9.2 kg / 20.2 lbs.
Relative humidity
0 to 95%, non-condensing
Cooling
Forced cooling with air inlets on front panel, air exit at rear
Power Requirements
Voltage range
90 to 264 V AC input
Line frequency
47 to 63 Hz
Consumption
400 W maximum (typical power consumption is 120 W)
Regulatory Compliance Standards
CFR 47, Part 15, Subpart B Class A Unintentional Radiators
CISPR 22:2008-09
EN 55022:2006 +A1:2007, Class A - Information Technology Equipment
CISPR 24:1997 +A1:2001, +A2:2002
EN 55024:1998 +A1:2001, +A2:2003 EMC Requirements - Information Technology Equipment - Immunity
Characteristics
Characteristics
IEC 61000-3-2:2005 / EN 61000-3-2:2006 Harmonic Currents, Class A
IEC 61000-3-3:2002 / EN 61000-3-
3:1995’ +A1:2001, +A2:2005 Flicker
Australia Radio Communications (Electromagnetic Compatibility) Standard 2008
CAN/CSA-C22.2 No. 60950-1-07
UL 60950-1 Ed. 2 Mar 27 2007
IEC 60950-1-am1 ed2.0 (2009-12), including all country and regional differences currently in force
EN 60950-1:2006+A1:2010