Cisco 1 GHz Surge-Gap Reverse Window Taps 安装指南
![Cisco](https://files.manualsbrain.com/attachments/7380d0050044647c30f5c24bbbf5d0c0b6d9bb84/common/fit/150/50/faa183d287233c52228cfea3dbc2a127fe780f60564fcb0955d9c3d1cd23/brand_logo.png)
Installing the Tap Housing on a Strand
4013399 Rev C
23
Installing the Tap Housing on a Strand
The strand-mounted configuration has the feeder cable entering one side of the unit
and exiting the other side. The unit has one strand clamp with a strand clamp bolt
and uses a standard cable strand for mounting.
and exiting the other side. The unit has one strand clamp with a strand clamp bolt
and uses a standard cable strand for mounting.
To Install the Tap Housing on a Strand
Follow these steps to install a tap housing on a strand.
1 Begin this procedure with the faceplate removed. Refer to To Remove the
1 Begin this procedure with the faceplate removed. Refer to To Remove the
Faceplate (on page 20).
2 Using a 3/8-in. wrench, loosen the strand clamp bolt.
3 Attach the housing to the strand making sure that the strand enters the strand
3 Attach the housing to the strand making sure that the strand enters the strand
clamp.
4 Secure the strand clamp to the strand by tightening the strand clamp bolt with a
3/8-in. wrench from 30 in-lb to 40 in-lb (3.4 Nm to 4.5 Nm).