(All CDE250 systems are pre-configured at the factory to first boot to external USB devices, 
followed by the internal compact flash.   If the system doesn’t automatically boot to the USB 
DOS stick, please verify the boot device priority in the BIOS.)    
  
6)  After the system boots into a DOS prompt, initiate the IPMI firmware upgrade by executing 
the IPMIUP.BAT DOS batch file. 
 
C:\> IPMIUP.bat 
 
The following will be displayed: 
 
Update IPMI FW to v3.06 
Current and proposed IPMI BIOS update versions 
… etc … 
 
Updating the IPMI FW to v3.06 
… etc … 
 
      The entire firmware upgrade should take approximately 10 minutes to complete. 
      Please wait for a positive acknowledge from the utility prior to rebooting.  
 
      
Please DO NOT power-cycle and/or interrupt the firmware upgrade process. 
      Doing so may result in the system being placed into a non-recoverable state. 
 
7)   After the IPMI firmware upgrade completes, you must power-cycle the system. 
 Of course, be sure to first remove the USB DOS stick prior to power-cycling. 
 
8)  It is recommended that the BMC/IPMI system be reset after the upgrade by removing  power 
from the power supplies waiting 10 seconds then replacing the power.  
2.2 IPMI  Firmware  Upgrade  Process  using  the  dedicated 
IPMI Ethernet port 
 
1)  Download the IPMI v3.06 firmware files to a remote desktop: 
a.  For VDS-TV these are contained in the ipmi306.zip downloaded from the 
“Download Link for IPMI FW v3.06 for VDS-TV Application” link contained in 
FN #63950: 
i.  Unzip ipmi306.zip to a temporary folder 
ii.  Note the location of the temporary folder 
 
b.  For VDS-IS these are contained in the vdsis-ipmi306.zip downloaded from the 
“Download Link for IPMI FW v3.06 for VDS-IS Application” link contained in 
FN#63950: 
i.  Unzip vdsis-ipmi306.zip to a temporary folder 
ii.  Note the location of the temporary folder