Cisco Model 6944 Four Port Optoelectronic Node 870 MHz with 42 54 MHz Split 数据表

下载
页码 14
Model 6944 Four Port Optoelectronic Node – 5-65/86-870 MHz 
 
12
 
 
Specifications 
 
Electrical 
Units
 
Notes 
Max. AC Through Current (continuous) 
Amps 
15 
 
Max. AC Through Current (surge) 
Amps 
25 
 
Component DC Power Consumption (typical) 
 
@ +24 VDC 
@ +15 VDC 
@ -6 VDC 
Launch Amplifier with 4 PHD hybrids 
Amps 1.68 
 
Standard (1X) Forward Configuration Module 
Amps 
0.42 
 
Dual (2X) Forward Segmentation Module 
Amps 
0.45 
 
Quad (4X) Forward Segmentation Module 
Amps 
0.90 
 
Standard (1X) Reverse Router Module 
Amps 
0.07 
 
Dual Segmentation (2X) Reverse Router Module 
Amps 
0.13 
 
Quad Segmentation (4X) Reverse Router Module 
Amps 
0.25 
 
Forward Redundancy Module 
Amps 
0.04 
 
 
 
Forward Narrowcast Module 
Amps 
0.04 
 
 
 
Status Monitoring Transponder 
Amps 
0.15 
 
Standard Optical Receiver 
Amps 
0.25 
0.01 
0.035 
 
High Gain Optical Receiver 
Amps 
0.35 
0.01 
0.035 
 
6940/44 Reverse Transmitter - High Gain FP 
Amps 
0.09 
0.07 
 
6940/44 Reverse Transmitter - High Gain DFB 
Amps 
0.09 
0.09 
 
6940/44 Reverse Switch 
Amps 
0.02 
 
 
 
 
 
 
 
Power Supply DC Current Rating 
Amps 
4.5 
0.5 
1.5 
Power Supply Operating Efficiency 
85  
 
AC Input Low Voltage Cutoff 
V AC 
33 
 
Minimum Restart Voltage 
V AC 
 41 
 
 
 Station Powering Data 
 
 
AC Voltage 
 
6944 Station 
DC 
(Amps at 
24 V DC)
 
 
90 
85 
80 
75 
70 
65 
60 
55 
50 
45 
41 
AC Current (A) 
 
1.1 1.2 1.2 1.2 1.2 1.2 1.2 1.5 1.6 1.8 2.0 
1x1 Configuration 
(1 Std Receiver  
& 1 DFB or FP 
Transmitter) 
 
2.59 
Power (W) 
75 75 75 74 74 74 74 74 74 75 76 
AC Current (A) 
 
1.3 1.3 1.3 1.3 1.3 1.4 1.6 1.7 1.8 2.0 2.3 
2x2 Configuration 
(2 Std Receivers  
& 2 DFB or FP 
Transmitters) 
 
2.96 
Power (W) 
86 86 86 86 86 85 85 86 86 86 87 
AC Current (A) 
 
1.6 1.7 1.7 1.8 1.8 1.9 2.2 2.3 2.5 2.8 3.2 
4x4 Configuration 
(4 Std Receivers  
& 4 DFB or FP 
Transmitters) 
 
4.09 
Power (W) 
120 120 119 119 119 119 120 120 120 121 121 
Data is based on stations configured for 2-way operation with status monitoring transponder.  AC currents specified are based on  
measurements made with typical CATV type ferro-resonant AC power supply (quasi-square wave), and standard version DC power 
supply (pn 590902). 
 
 
 
Environmental 
Units 
 
Operating Temperature Range 
degrees 
-40
°
C to 60
°
C  (-40
°
F to 140
°
F) 
Relative Humidity Range 
percent 
5% to 95% 
Mechanical  
 
 
Housing Dimensions 
Weight 
Station with 2 RX, 2 TX, 2 power supplies:  17.7 kg (39 lbs) 
51.3 cm L x  27.4 cm H x 27.4 cm D 
(20.2 in. L x 10.8 in. H x 10.8 in. D ) 
Station with 4 RX, 4 TX, 2 power supplies:  19.1 kg (42 lbs) 
 
Note: 
1.  The total DC power consumption of installed components should not exceed the power supply DC current rating.