Cisco Model 6940 Four Port Optoelectronic Node 870 MHz with 55 70 MHz Split 数据表

下载
页码 8
Model 6940 Optoelectronic Node - 5-55/70-870 MHz 
 
3
 
 
Optical Section Specifications
 
 
Optical Section 
 - Forward Receiver (RX) Module 
 
Units 
 
Standard RX 
 
High Gain RX 
 
Notes 
Wavelength 
nm 
1310 and 1550 
1310 and 1550 
 
Optical Input Range 
dBm 
-3 to +2.0 
-3.0 to +1.0 
 
Pass Band 
MHz 
52-870 
52-870 
 
Frequency Response  
dB 
± 0.75 
± 0.75 
Tilt  (
±1.5 dB) 
dB 0 
0   
Optical Input Test Point (
± 20 %) 
V DC 
1V / mW 
1V / mW 
RF Output Test Point (± 1.0 dB) 
dB 
- 20 
- 20 
 
RF Output Level  
dBmV 
See Chart Below 
See Chart Below 
 
 
Receiver RF Output Level Vs Transmitter OMI  
 
Standard 
Receiver 
 
   High 
Gain 
Receiver 
 
19.5
20.0
20.5
21.0
21.5
22.0
22.5
23.0
23.5
24.0
24.5
25.0
25.5
26.0
2.
25%
2.
50%
2.
75%
3.
00%
3.
25%
3.
50%
3.
75%
4.
00%
Transmitter OMI per Channel
Minimum
RF Output 
Level 
(dBmV)
with 
0 dBm 
Optical 
Input 
Power
1310 nm
1550 nm
30.5
31.0
31.5
32.0
32.5
33.0
33.5
34.0
34.5
35.0
35.5
36.0
36.5
37.0
37.5
2.
25
%
2.
50
%
2.
75
%
3.
00
%
3.
25
%
3.
50
%
3.
75
%
4.
00
%
Transmitter OMI per Channel
Minimum
RF Output 
Level 
(dBmV)
with 
0  dBm 
Optical 
Input Power
1310 nm
1550 nm
 
 
Notes for Optical Section Specifications: 
1. 
For forward receiver module only.  Does not include frequency response contributions from forward optical transmitter. 
2. 
Referenced to optical input power in milliwatts at 1310 nm.   
3. 
Minimum receiver RF output level for the stated transmitter percent Optical Modulation Index (OMI) per channel, with receiver optical 
input power of 0 dBm.  To determine RF output levels at other optical input power, add (or subtract) 2 dB in RF level for each 1 dB 
increase (or decrease) in receiver optical input power.  
 
 
For reverse optical transmitter and link performance, see the “Analog Reverse Optical Transmitters for Model 
6940/6944 and GainMaker
®
 Optoelectronic Stations” data sheet or the “Model 6940/44 bdr Digital Reverse” data 
sheet(s). 
 
 
 
 
 
 
 
 
 
 
Unless otherwise noted, the above specifications reflect typical station performance at stated reference levels in the recommended 
operating configuration (s), and are based on measurements made in accordance with NCTA Recommended Practices for 
Measurements on Cable Television Systems using standard frequency assignments and are referenced to 20°C (68°F).