Cisco Headend System Release 2.7 设计指南

下载
页码 124
 
 
SDV System Communications Alarms 
4002915 Rev B 
31 
 
 
 
SDV Server Trap 6 (6 Hex) 
Alarm Summary: 
SDV Server Failed to Communicate with Edge Device 
Description: 
This alarm occurs when the SDV SRM process cannot ping the edge device or QAM 
modulator. 
Severity: 
Major 
Service Impact: 
When this alarm occurs, an SDV program cannot be established on the edge device. 
Check and Correct: 
Possible Cause 
Check and Correct Instructions 
The network between the SDV server and 
the edge device is not responding. 
Try to ping the edge device and/or 
query it through SNMP using an 
alternate route (for example, not 
through the SDV server). 
If the edge device responds, the 
problem is probably within the network 
between the edge device and SDV 
server. 
If the edge device does not respond, 
then proceed to the next possible 
cause. 
Check and verify the amount of 
bandwidth allotted for your service 
groups. 
The edge device is not responding. 
Try to assess the cause of the failure, and 
then reset the QAM device to restore 
service.