Chapter 5  Maintenance 
 
 
 
150 
OL-29643-02 
into the optical module. Follow these steps to clean fiber optic connectors that will be 
connected to the optical module: 
Important: Before you begin, remove optical power from the module or ensure that 
optical power has been removed. 
1  Inspect the connector through an optical connector scope. If the connector is 
damaged, e.g., scratched, burned, etc., replace the jumper. 
2  If the connector is dirty but otherwise undamaged, clean the connector as 
follows: 
a  Make several swipes across the face of the connector with the appropriate 
ferrule cleaner. This will remove dust and some films. 
b  Listen for a slight "squeak" typically generated during this process, indicating 
a clean connector. 
c  Inspect the connector again through the scope to confirm that it is clean. 
3  If a second inspection indicates that further cleaning is needed: 
a  Use 99% isopropyl alcohol and a lint-free wipe to clean the connector. 
b  Use the appropriate ferrule cleaner again to remove any film left over from 
the alcohol. 
c  Inspect the connector again through the scope and confirm that it is clean. 
4  If necessary, repeat steps 3a-3c until the connector is clean. 
Cleaning Bulkheads 
Note: It is generally more difficult to clean bulkhead connectors and verify their 
condition due to limited accessibility of the fiber end face. For this reason, even on 
products with accessible bulkhead connectors, you should only attempt to clean a 
bulkhead connector when a dirty connector is indicated. 
Follow these steps to clean the bulkhead: 
    WARNING: 
 
Avoid personal injury! Use of controls, adjustments, or performance of 
procedures other than those specified herein may result in hazardous 
radiation exposure.
 
 
Avoid personal injury! The laser light source on this equipment emits 
invisible laser radiation. Avoid direct exposure to the laser light source.
 
 
Avoid personal injury! Viewing the laser output with optical instruments 
(such as eye loupes, magnifiers, or microscopes) may pose an eye hazard.
 
1  Insert a dry bulkhead swab into the bulkhead and rotate the swab several times. 
2  Remove the swab and discard. Swabs may be used only once. 
3  Check the bulkhead optical surface with a fiber connector scope to confirm that it 
is clean. If further cleaning is needed: 
a  Moisten a new bulkhead swab using a lint-free wipe moistened with 
optical-grade (99%) isopropyl alcohol. 
b  With the connector removed, fully insert the bulkhead swab into the