Cisco Headend System Release 2.7 安装指南

下载
页码 142
 
Chapter 1    SR i4.2.2 DVD Pre-Upgrade Procedures 
 
 
 
30 
4036631 Rev B 
Stop the dhctStatus, signonCount and cmd2000 
Processes 
When sites are being upgraded, the dhctStatus utility may occasionally be in the 
process of polling DHCTs. Additionally, the signonCount utility may be active in 
system memory. Our engineers have discovered that upgrades proceed more 
smoothly when the dhctStatus utility is not actively polling DHCTs and when the 
signonCount utility is not active in system memory. The instructions in this section 
guide you through the steps to terminate polling associated with the dhctStatus 
utility and to remove the signonCount utility from system memory. 
 
Terminating the dhctStatus Polling Operation 
Follow these instructions to determine whether the dhctStatus utility is actively 
polling DHCTs, and then to terminate the polling operation, if necessary. 
1  From a root xterm window, type ps -ef | grep dhctStatus and then press Enter
The system reveals whether there are any instances of the dhctStatus process 
running. 
2  Did your results from step 1 show that the dhctStatus process was running? 
 
If yes, go to step 3 to shut down the polling operations. 
 
If no, skip the rest of this procedure and go to Removing the signonCount 
Utility from System Memory
 (on page 27). 
3  Type dhctStatus and press Enter to display the dhctStatus menu. 
4  To terminate the polling operation, follow these instructions. 
a  Type p and then press Enter. The system displays a polling menu. 
b  Type and then press Enter. The system terminates the polling operation. 
c  Press Enter to return to the main menu. 
d  Type and then press Enter to exit the menu. 
5  Type ps -ef | grep dhctStatus and then press Enter to determine whether all of 
the processes have been terminated. 
6  Type kill  -9  [ process ID ] and then press Enter for any process ID displayed in 
the results from step 5. 
Note:  The process ID(s) to kill is/are located starting with the second column of 
the output from step 5. 
7  Repeat steps 5 and 6 for any process that continues to remain active.