Cisco Headend Digital Broadband Delivery System 發佈版本通知
SR 2.8 at a Glance
4019364 Rev B
15
CR 88387: VOD Session Transaction Graph Does Not Update Correctly In Dashboard
The VOD Session Transaction graph in the Dashboard does not update as often as
expected.
expected.
CR 88689: First Row Does Not Load for a Table-Based QAM
When users configure session data for new table-based QAM modulators, the first
record of the table may not be loaded.
record of the table may not be loaded.
CR 89253: DNCS Allows User to Assign Reserve PID in ECM PID Range
When the user builds a TSR on the GQAM, the ECM PID range in the WUI allows
the user to assign the starting PID as 1. This PID is currently reserved as the CAT
PID. This causes an interruption of services on third-party QAM devices.
the user to assign the starting PID as 1. This PID is currently reserved as the CAT
PID. This causes an interruption of services on third-party QAM devices.
Important: Be careful that you do not assign the starting PID in the ECM PID range
as 1.
as 1.
CR 89326: User Can Configure Generic QAM with IP Address That Has Already Been Assigned
to a Netcrypt
to a Netcrypt
The DNCS allows users to configure a generic QAM with an IP address that has
already been assigned to a Netcrypt. If two devices have the same IP address, the
DNCS will encounter problems using the GQI to talk to generic QAMs.
already been assigned to a Netcrypt. If two devices have the same IP address, the
DNCS will encounter problems using the GQI to talk to generic QAMs.
CR 89452: OOB Bridge GUI Does Not Include All CCM Values In Drop-Down List
The CableCARD module ignores the DCM when the CableCARD Comm Mode field
is present. Instead, the GUI defaults to CableCARD Comm Mode value ADSG-IM-
CC. This may cause problems with the client boot-up.
is present. Instead, the GUI defaults to CableCARD Comm Mode value ADSG-IM-
CC. This may cause problems with the client boot-up.
CR 89529: Newly Created BT Header Bridges Are Not Receiving SI
Newly created BT header bridges do not indicate any SI traffic at all.
Workaround: After creating the BT header bridge, change the bridge to an ADSG
bridge and then back to a BT header bridge.
bridge and then back to a BT header bridge.
CR 90140: CMTS Bridge Advanced ADSG with BT Headers Allows SI and EAS Flag Enabled
Simultaneously
Simultaneously
The CMTS Bridge Advanced ADSG with BT Headers GUI should not allow the SI
and EAS flags to be enabled at the same time. For Direct ADSG, you cannot have SI
and EAS on the same bridge.
and EAS flags to be enabled at the same time. For Direct ADSG, you cannot have SI
and EAS on the same bridge.
CR 90883: Recapture BW Changes at Service Group UI Are Not Updated at SDV Server
Any changes made to the Recapture BW field in the Service Group user interface are
not reflected at the SDV server. The SDV server still shows the original values.
not reflected at the SDV server. The SDV server still shows the original values.