Cisco Model 6109 6 MHz Off-Air Reference (NTSC) 技术参考

下载
页码 4
 
 
 
Operations Alert Bulletin 
Recovering From a Failure of the 
camAuditor Process 
Background 
Our engineers are aware of a rare condition that can cause the camAuditor 
process of the Digital Network Control System (DNCS) to fail. When the 
camAuditor process fails, Entitlement Management Messages (EMMs) are not 
updated and the emmDistributor process transmits expired EMMs to Digital 
Home Communication Terminals (DHCTs). When DHCTs fail to receive updated 
EMMs, they may time out and become inoperative.  
Although rare, this condition is most likely to manifest itself under one of the 
following circumstances: 
 
DNCS processes are restarted all together (using dncsStart
 
The cam processes are started as a group (rather than element by element) 
through the dncsControl utility 
Should the camAuditor process fail under these circumstances, the indicator light 
for the camAuditor process will still illuminate green on the DNCS Control 
window, so system operators will not know that the camAuditor process has 
failed. Therefore, system operators should monitor their system for the three 
following symptoms that indicate that the camAuditor process may have failed. 
 
The field in the Doctor Report called DHCTs with EMMs Expiring in 15 Days 
indicates that the site has DHCTs with EMMs expiring in 15 days or less. 
Important:  Our engineers wish to remind system operators to run the Doctor 
Report daily. 
 
Output from the smMix utility shows in-service DHCTs set to expire within 20 
days. 
 
The log file for the camAuditor process shows no entries. 
Our engineers have assigned Change Request (CR) 84069 to this issue and are 
actively working on a solution. 
Recovery from the failed camAuditor process is easy and is described in the 
following section, Recommendation