Cisco Compact Outdoor Amplifier Model 93412 安装指南

下载
页码 2
 
Compact Dual Output EGC Amplifier A93270 and Compact Single 
Output EGC Amplifier A93280 Housing Closure Instructions 
Closing the Housing 
Introduction 
This document provides instructions for correctly closing the Compact Dual 
Output EGC Amplifier A93270 and the Compact Single Output EGC Amplifier 
A93280 housings. 
Important:  For complete information about Safety Instructions, Installation and 
Operation of the Compact Dual Output EGC Amplifier A93270 or the Compact 
Single Output EGC Amplifier A93280, refer to the Compact Dual Output EGC 
Amplifier A93270 Installation and Operation Guide
, part number 4029501, or the 
Compact Single Output EGC Amplifier A93280 Installation and Operation 
Guide
, part number 4038501. 
Tightening the Housing Closure Bolts 
To tighten the housing closure bolts, follow the steps below. 
Important:  Before you start, make sure you have a 5-mm Allen wrench. 
CAUTION: 
Avoid moisture damage and RF leakage!  Follow the procedure exactly as 
shown below to ensure a proper seal. 
 
1. 
Inspect the housing gasket and all mating surfaces. Wipe off any dirt and 
debris. 
2. 
Close the housing and finger-tighten all closure bolts. 
3. 
Use the Allen wrench to tighten each closure bolt from 5 Nm to 6.5 Nm (3.7 ft-
lb to 4.8 ft-lb). 
Important:  Follow this numbered sequence to tighten the closure bolts. 
 
Continued on next page