Important Safety Instructions
, continued
 
Grounding (Utility AC Powered Equipment in Pedestals, Service Closets, etc.) 
This section provides instructions for verifying that the equipment is properly grounded. 
Safety Plugs (USA Only) 
This equipment is equipped with either a 2-terminal (polarized) safety plug. The wide blade 
or the third terminal is provided for safety. Do not defeat the safety purpose of the 
grounding-type or polarized safety plug. 
To properly ground this equipment, follow these safety guidelines: 
 
Polarized Plug - For a 2-terminal plug (a polarized plug with one wide blade and one 
narrow blade), insert the plug into a polarized mains, 2-terminal outlet in which one socket 
is wider than the other. 
Note:  If this plug cannot be fully inserted into the outlet, try reversing the plug. If the plug 
still fails to fit, contact an electrician to replace the obsolete 2-terminal outlet. 
Grounding Terminal 
If this equipment is equipped with an external grounding terminal, attach one end of an 
AWG18 wire (or larger, it should be green with yellow strip if insulated wire used) or bare 
CU wire to the grounding terminal; then, attach the other end of the wire to a ground, such 
as a grounded equipment rack. 
Safety Plugs (European Union) 
 
Class II Mains Powered Equipment – Provided with a 2-terminal AC inlet that may be 
connected by a 2-terminal power cord to the mains supply outlet. No connection to the 
protective ground is required as this class of equipment is provided with double or 
reinforced and/or supplementary insulation in addition to the basic insulation provided in 
Class I equipment. 
Note:  Class II equipment, which is subject to EN 50083-1, is provided with a chassis 
mounted equipotential bonding terminal. See the section titled Equipotential Bonding for 
connection instructions.   
Equipotential Bonding   
If this equipment is equipped with an external chassis terminal marked with the IEC 60417-
5020 chassis icon (
), the installer should refer to CENELEC standard EN 50083-1 or IEC 
standard IEC 60728-11 for correct equipotential bonding connection instructions. 
General Servicing Precautions 
 
  WARNING: 
Avoid electric shock! Opening or removing this equipment’s cover may expose you to 
dangerous voltages. 
 