Cisco Laser Link Mainframes 安装指南

下载
页码 63
78-4004177-01 Rev D 
Setup and Operation 
3-23 
Alarm Tables,
 Continued 
1550 nm DFB Reverse Transmitters Alarm Table 
 
Models 
(front panel 
label) 
Description 
Vital Sign 
VS#/Pin# 
Vital Sign Description 
Logic 
LLNTR 
Laser Link LLNTR 5-
210 MHz 1550 nm 
reverse transmitter 
for DWDM 
applications 
#1/#5 
  
  
  
#2/#11 
#3/#12 
#4/#4 
Redundant Power Alarm 
– active when module 
detects loss of +24 V DC 
“A” supply 
Optical Output Power 
Laser Bias Current  
Global Alarm – +5 V DC 
fails, laser temp ±5%, laser 
bias current ±10%, optical 
power – 25%, “A” supply 
fails 
0 V = normal 
+5 V = alarm 
  
  
1 V/mW 
1 V/50 mA 
24 V = normal 
0 V = alarm 
 
Switch Module Alarm Table 
 
Models 
(front panel 
label) 
Description 
Vital Sign 
VS#/Pin# 
Vital Sign Description 
Logic 
LLRS 
Laser Link LLRS RF 
switch, half-width 
module 
#1/#5 
  
  
  
#2/#11 
  
#3/#12 
  
  
#4/#4 
Redundant Power Alarm 
– active when module 
detects loss of +24 V DC 
“A” supply 
Switch Mode 
  
Switch position “x” port 
connected to common 
port 
Global Alarm – “A” 
supply fails switch 
position B, switch failure 
0 V = normal 
+5 V = alarm 
  
  
0 V = auto mode 
5 V = local mode 
0 V = A 
5 V = B 
  
24 V = normal 
0 V = alarm