Operating using ICIM LCD, Continued 
Alarm Code List 
The table below lists the alarm information of the OptoStar II 1550 nm optical 
amplifier module. 
Code  Item 
Condition 
LED 
001 
Low Optical Input 
Power 
Optical input power is 
lower than -5.0 dBm 
Alarm LED is red 
002 
High Optical Input 
Power 
Optical input power is 
higher than +10 dBm 
Alarm LED is red 
003 
Low Optical Output 
Power 
Optical output power is 
4.0 dB lower than 
standard value (factory 
setting) 
Alarm LED is red 
004 
High Optical 
Output Power 
Optical output power is 
1.0 dB higher than 
standard value (factory 
setting) 
Alarm LED is red 
005 
High Drive Current 
of Pump 1   
Drive current of pump 1 is 
too high (different pumps 
have different thresholds; 
pre-set before delivery)   
Alarm LED is red 
006 
High Drive Current 
of Pump 2 
Drive current of pump 2 is 
too high (different pumps 
have different thresholds; 
pre-set before delivery)   
Alarm LED is red 
007 
High TEC Current 
of Pump 1 
TEC current of pump 1 is 
higher than 1.3A 
Alarm LED is red 
008 
High TEC Current 
of Pump 2 
TEC current of pump 2 is 
higher than 1.3A 
Alarm LED is red 
009 
Abnormal LD 
Temperature of 
Pump 1   
LD temperature of pump 
1 is higher than 50℃  or 
lower than 35℃ 
Alarm LED is red 
010 
Abnormal LD 
Temperature of 
Pump 2 
LD temperature of pump 
2 is higher than 50℃  or 
lower than 35℃ 
Alarm LED is red 
011 
High Module 
Temperature 
Module temperature 
higher than 70°C 
Alarm LED is red 
012 
EDFA Internal 
Module Failure   
EDFA internal module has 
communication failure   
Alarm LED is red 
 
 
 
 
 