Cisco Cisco OptoStar II Driver Amplifier 安装指南

下载
页码 75
General Troubleshooting Information, Continued 
Troubleshooting 
If the red alarm indicator on the front panel of the module is illuminated, check 
the OptoStar II ICIM display, the OptoStar II Console, or the OptoStar II NMS for 
alarm code. See Alarm Code List (on page 3-13) to determine the cause of the 
alarm. See the table below. 
Alarm 
Possible Cause 
Servicing Instruction 
High/Low DC 
Output   
Circuit failure 
Contact the manufacturer for 
servicing 
Fan failure inside 
the chassis/power 
supply module 
Fan Failure   
Replace the fan, or contact 
the manufacturer for 
servicing 
High Module 
Temperature 
 
High ambient 
temperature leading 
to insufficient heat 
dissipation 
 
Poor chassis 
ventilation 
 
Fan Failure   
 
Ensure good ventilation   
 
Put the chassis in a place 
with good ventilation 
 
In case of fan failure, 
replace the fan, or 
contact the 
manufacturer for 
servicing 
 
  CAUTION: 
Do not open the enclosure of this module in any case. Opening the enclosure 
may result in equipment damage, and you may lose the warranty eligibility. 
 
 
 
 
4-4 
  Troubleshooting 
OL-29659-03