Operating using ICIM LCD, Continued 
Sub-menu 2 -- RF Input Alarm Threshold 
The illustration below shows sub-menu 2 of the OptoStar II forward driver 
amplifier module - RF Input Alarm Threshold.   
 
The lower limit of the factory setting of the RF input alarm threshold is 10 dBmV 
and upper limit is 20 dBmV. If the input signal has both analog signal and digital 
signal, the RF input alarm threshold is subject to the analog signal.   
The cursor stays in the “Low” field by default.   
• 
To configure the lower limit of the RF input alarm threshold (minimum input 
level is no less than 10 dBmV) 
1.  Press SET button to start the configuration; 
2.  Press ▲▼ buttons to change the value, and press SET button to confirm; 
3.  Press ► button to move the cursor to “Set”; 
4.  Press SET button to save the configuration. 
• 
To configure the upper limit of the RF input alarm threshold (maximum input 
level is no more than 20 dBmV) 
1.  Press ▼ button to leave the cursor in the “High” field; 
2.  Press SET button to start the configuration; 
3.  Press ▲▼ buttons to change the value, and press SET button to confirm; 
4.  Press ► button to move the cursor to “Set”; 
5.  Press SET button to save the configuration. 
 
 
Continued on next page 
 
 
3-10 
 
Operation 