General Information 
1-5 
Laser Link III Mainframe Description,
 Continued 
Important:  Wire gauge specifications for 24 V DC/15 A input are as follows: 
10’ cable:  12 AWG minimum 
5’ cable:  15 AWG minimum 
Terminal Block 
Normally open (NO) and normally closed (NC) contact points are available on the 
terminal block (J11) of the power distribution board.  These interface points allow 
you to trigger an external alarm should the general operation alarm of the 
mainframe toggle to an alarm state.  The number five position of the terminal block 
may be utilized in conjunction with the common position, number six, in a normally 
closed alarm relay.  The number seven pin may be used in conjunction with the 
common position in a normally open alarm relay configuration.  Under normal 
operation (no alarm), number six and number five are closed. 
Status Monitoring 
Status of housed modules is supplied to users via front panel LEDs, or the ROSA
 
Element Management System, or TNCS Element Management System (if used).  The 
available monitored parameters are provided in the respective module manuals. 
Status monitoring signals are routed from the rear of the module to the power 
distribution board.  This is accomplished by connecting the module’s DB15, DB26, or 
DB9 connector to the respective DB26 connector on the power distribution board 
using the interface cable provided with each module.  From the board, signals are 
available to the user panel (J12), the element management system interface point (J8), 
and the telemetry interface point (J9A and J9B).