Setup and Operation 
3-7 
Laser Link III Mainframe Controls and Indicators,
 Continued 
Status Monitoring Module 
The following table describes the indicators and test points on the Status Monitoring 
module. 
 
Indicator/Test Point 
Description 
PWR A LED 
Indicates operational status of power supply A: 
• 
Green indicates proper operation 
• 
Red indicates a power supply A malfunction (voltage 
too high or too low) 
Note:  Function is controlled by position of the Redundant 
Power/“B” Alarm switch. 
PWR B LED 
Indicates operation of a redundant power supply: 
• 
Green indicates proper operation 
• 
Red indicates a malfunction (voltage too high or too 
low) 
Note:  If a redundant power supply is not present, the 
LED will be extinguished.  Function is controlled by 
position of the Redundant Power/“B” Alarm switch. 
ALARM LED 
Indicates alarm condition: 
• 
Normally extinguished 
• 
Red indicates the presence of a general alarm condition 
with the power supplies or a housed module 
• 
Flashing red indicates fan failure 
+24 V A Test Point 
Test point for the output of power supply A. 
GND Test Point 
Ground point. 
+24 V B Test Point 
Test point for the output of power supply B. 
Ground Symbol 
Plug-in for electrostatic wrist strap.  Use of an electrostatic 
wrist strap is recommended whenever plug-in modules 
are going to be removed.