2-20 
Installation 
78-748704-01 Rev C 
Alarm I/O Connections,
 Continued 
Wiring Alarm Contacts for External Redundancy 
When a critical alarm occurs in the master optical receiver, the master is disabled 
and the redundant optical receiver is enabled.  If the redundant optical receiver is 
external (not in the same processor module as the master), the contacts from the 
master optical receiver’s pin on the ALARMS OUT connector must be wired to the 
contacts at the redundant optical receiver’s pin on the ALARMS IN connector of the 
chassis containing the redundant optical receiver.  See the previous pages for pin 
locations. 
Important:  For external redundancy to function, the connection described above 
must be made when the redundant optical receiver is: 
• 
In the same chassis (but a different processor) as the master. 
• 
In a different chassis from the master. 
Once the contacts are wired, care must be taken to ensure that the master and 
redundant optical receivers do not change slots.  Otherwise, the ALARMS IN and 
ALARMS OUT connectors will need to be rewired. 
Notes: 
• 
Any device configured as a master ignores its ALARMS IN contacts. 
• 
To verify proper wiring and configuration, simply unplug the master device and 
make sure the redundant optical receiver turns on.