Cisco Cisco SG500-52PP 52-port Gigabit Max PoE+ Stackable Managed Switch 技术参考

下载
页码 1180
Remote Network Monitoring (RMON) Commands
78-21491-01 Command Line Interface Reference Guide
371
23
 
Example
The following example displays the RMON event table.
The following table describes significant fields shown in the display:
23.10 show rmon log
Use the show rmon log EXEC mode command to display the RMON log table.
Syntax
show rmon log [
event
]
Parameters
event—Specifies the event index. (Range: 0–65535)
Command Mode
EXEC mode
switchxxxxxx# show rmon events
Index
-----
1
2
Description
-----------
Errors
High 
Broadcast
Type
------
Log
Log
Trap
Community
---------
router
Owner
------
CLI
Manager
Last time sent
------------------
Jan 18 2006 23:58:17
Jan 18 2006 23:59:48
Field
Description 
Index
Unique index that identifies this event.
Description
Comment describing this event.
Type
Type of notification that the device generates about this event. 
Can have the following values: none, log, trap, log-trap. In the 
case of log, an entry is made in the log table for each event. In 
the case of trap, an SNMP trap is sent to one or more 
management stations.
Community
If an SNMP trap is to be sent, it is sent with the SNMP community 
string specified by this octet string.
Owner
The entity that configured this event.
Last time 
sent
The time this entry last generated an event. If this entry has not 
generated any events, this value is zero.