Intel X5667 AT80614005154AB 用户手册
产品代码
AT80614005154AB
Intel
®
Xeon
®
Processor 5600 Series Datasheet Volume 1
127
Thermal Specifications
Notes:
1.
The Thermal Profile is representative of a volumetrically constrained platform. Please refer to
for
discrete points that constitute the thermal profile.
2.
Implementation of the nominal and short-term Thermal Profiles should result in virtually no TCC activation.
Utilization of thermal solutions that do not meet the Thermal Profile will result in increased probability of
TCC activation and may incur measurable performance loss.
3.
The Nominal Thermal Profile must be used for all normal operating conditions, or for products that do not
require NEBS Level 3 compliance.
4.
The Short-Term Thermal Profile may only be used for short-term excursions to higher ambient operating
temperatures, not to exceed 96 hours per instance, 360 hours per year, and a maximum of 15 instances
per year, as compliant with NEBS Level 3. Operation at the Short-Term Thermal Profile for durations
exceeding 360 hours per year violate the processor thermal specifications and may result in permanent
damage to the processor.
5.
Refer to the Intel® Xeon® Processor 5500/5600 Series Thermal/Mechanical Design Guide for system and
environmental implementation details.
Figure 7-10. LV-40W Processor Dual Thermal Profile
Table 7-19. LV-40W Processor Dual Thermal Profile
Power (W)
Nominal T
CASE_MAX
(°C)
Short-term T
CASE_MAX
(°C)
0
50
65
5
53
68
10
56
71
15
58
73
20
61
76
25
64
79
30
67
82
35
69
84
40
72
87