Brother RJ-4040 参考指南

下载
页码 48
Raster Command Reference 
 
 
- 31 - 
5. MCR Command Specifications 
5. MCR Command Specifications 
5.1. Command details 
ESC #1 
MCR on command 
ASCII: 
ESC 
{n1} 
{n2} 
{n3} 
Hexadecimal:  1B 
23 
31 
{n1} 
{n2} 
{n3} 
Description 
  Turns on MCR. Does nothing if it is already on.   
  Definitions of {n1} through {n3} 
{n1}: 
Set read/response mode 
    00h: 
Continuous reading mode 
    01h: 
Single reading mode (Reading ends even if it failed) 
*Does nothing if none of the above 
{n2}: 
Timeout setting (seconds, 1 (min.) to 255 (max.)); 0 (00h) indicates no timeout. 
{n3}: 
Read track setting 
{n3} 
Read track 
Track3 
Track2 
Track1 
1 (01h) 
○ 
2 (02h) 
○ 
3 (03h) 
○ 
○ 
4 (04h) 
○ 
5 (05h) 
○ 
○ 
6 (06h) 
○ 
○ 
7 (07h) 
○ 
○ 
○ 
*7 (07h) if other than 1 through 7 
 
 
ESC #0 
MCR off command 
ASCII: 
ESC 
Hexadecimal:  1B 
23 
30 
Description 
  Turns off MCR. Does nothing if it is already off.